Room-Level IAQ Sensing
Monitor PM2.5, CO₂, TVOC, temperature and humidity independently in each room through controllers with integrated multi-parameter sensing.
ROOM-LEVEL DEMAND-CONTROLLED VENTILATION
Connect room measurements with the master controller, fresh-air unit and zone dampers. Select A54 CO₂ sensing, embedded CO₂ modules or the multi-sensor platform for the room interface. Use compatible ventilation controllers or an integrated IAQ thermostat to coordinate the configured delivery strategy.
When indoor air quality deteriorates in a specific room, the system can coordinate the fresh-air unit and corresponding motorized zone damper to direct airflow precisely where it is needed. This helps avoid unnecessary whole-home ventilation, reduce the energy required to filter, heat or cool outdoor air, and maintain healthier indoor conditions throughout the home.
Monitor PM2.5, CO₂, TVOC, temperature and humidity independently in each room through controllers with integrated multi-parameter sensing.
Adjust delivery around room demand while maintaining the minimum ventilation and operating limits configured for the project.
Coordinate the fresh-air system with motorized zone dampers to deliver air to the rooms that need it while reducing unnecessary air treatment elsewhere.
FROM ROOM IAQ TO PRECISE FRESH AIR
MAXMAC transforms real-time indoor air quality measurements from individual rooms into targeted ventilation actions. Instead of treating the entire home whenever one area requires fresh air, the system identifies actual room demand and coordinates the fresh-air unit and zone dampers accordingly.
01 · Sense


Multi-parameter IAQ sensing integrated into each room controller continuously monitors the air where occupants actually live.
02 · Evaluate
The system evaluates each room independently to determine where and when indoor air quality requires improvement.
03 · Coordinate
Room-level demand is translated into coordinated commands for the fresh-air unit and corresponding motorized zone dampers.
04 · Deliver
Fresh air is directed to the affected room without unnecessarily ventilating and conditioning the entire home.
Compatible Fresh-Air EquipmentFresh-Air Unit · ERV · HRV
MAXMAC Motorized Air Distribution BoxDirects supply air to individual rooms
Master / Slave IAQ ControllersMonitor rooms and coordinate ventilation demand











WHOLE-HOME DCV ARCHITECTURE
The MAXMAC whole-home DCV architecture connects room controllers with integrated IAQ sensing to a master control interface, fresh-air equipment and motorized zone dampers. Each room reports its own air quality conditions, allowing the system to coordinate ventilation demand and airflow independently across the home.
Integrated controllers monitor the air where occupants actually live.
The master controller makes every room’s IAQ status and ventilation demand visible from one interface.
Each motorized damper regulates fresh-air delivery according to its room’s actual demand.


MODULAR ZONED AIR DISTRIBUTION
MAXMAC’s motorized zone damper can plug directly into the compatible plenum box, creating a compact and modular air-distribution assembly for whole-home demand-controlled ventilation.
Each connected damper independently regulates airflow to its assigned room. This allows the system to expand by zone, simplifies installation and helps deliver fresh air precisely where real-time indoor air quality data indicates it is needed.
Discuss Your Zoned Airflow ProjectIAQ-BASED FRESH-AIR CONTROL
Traditional ventilation systems often rely on fixed schedules or air quality measurements collected from a central duct. These measurements cannot accurately represent the conditions of every room and may cause the entire home to be ventilated when only one area requires fresh air.
MAXMAC integrates multi-parameter IAQ sensing directly into room controllers, allowing the system to monitor PM2.5, CO₂, TVOC, temperature and humidity where occupants actually live. When air quality deteriorates in one room, the fresh-air system can respond specifically to that room while maintaining the minimum airflow configured for other rooms.
By reducing unnecessary airflow, the system also helps reduce the energy used to filter, heat or cool incoming outdoor air.
Design Resources
Use the relevant guide when reviewing the sensing, control or installation choices for this solution.

Design Resource
Understand NDIR concentration measurement and its role as a controller input.
Read the Guide
Design Resource
Review the relationship between room measurements, the thermostat and connected equipment.
Read the Guide
Design Resource
Review sensor combinations, host interfaces and integration choices for an IAQ device.
Read the GuideShare the room layout, fresh-air equipment and minimum ventilation requirements. We can help you review sensing, controls and zoned delivery.