ROOM-LEVEL DEMAND-CONTROLLED VENTILATION

Room-Level IAQ Sensing & Zoned Ventilation Control for Whole-Home Systems

Connect room measurements with the master controller, fresh-air unit and zone dampers. Select A54 CO₂ sensing, embedded CO₂ modules or the multi-sensor platform for the room interface. Use compatible ventilation controllers or an integrated IAQ thermostat to coordinate the configured delivery strategy.

When indoor air quality deteriorates in a specific room, the system can coordinate the fresh-air unit and corresponding motorized zone damper to direct airflow precisely where it is needed. This helps avoid unnecessary whole-home ventilation, reduce the energy required to filter, heat or cool outdoor air, and maintain healthier indoor conditions throughout the home.

01

Room-Level IAQ Sensing

Monitor PM2.5, CO₂, TVOC, temperature and humidity independently in each room through controllers with integrated multi-parameter sensing.

02

Ventilation Based on Actual Demand

Adjust delivery around room demand while maintaining the minimum ventilation and operating limits configured for the project.

03

Precision Zoned Air Delivery

Coordinate the fresh-air system with motorized zone dampers to deliver air to the rooms that need it while reducing unnecessary air treatment elsewhere.

FROM ROOM IAQ TO PRECISE FRESH AIR

Turn Real-Time Room-Level IAQ Data into Demand-Controlled Fresh-Air Delivery

MAXMAC transforms real-time indoor air quality measurements from individual rooms into targeted ventilation actions. Instead of treating the entire home whenever one area requires fresh air, the system identifies actual room demand and coordinates the fresh-air unit and zone dampers accordingly.

01 · Sense

Integrated Room-Level IAQ Sensing

MAXMAC integrated IAQ fresh-air controller
Integrated IAQ ControllerBuilt-In Multi-Parameter Sensing
Configurable
MAXMAC A54 multi-parameter IAQ sensor
A54 IAQ SensorConfigurable Multi-Parameter Sensor

Multi-parameter IAQ sensing integrated into each room controller continuously monitors the air where occupants actually live.

PM2.5CO₂TVOCTemperatureHumidity

02 · Evaluate

Identify Ventilation Demand by Room

The system evaluates each room independently to determine where and when indoor air quality requires improvement.

03 · Coordinate

Control Fresh-Air Equipment and Zone Dampers

Room-level demand is translated into coordinated commands for the fresh-air unit and corresponding motorized zone dampers.

04 · Deliver

Send Fresh Air Only Where It Is Needed

Fresh air is directed to the affected room without unnecessarily ventilating and conditioning the entire home.

Compatible whole-home fresh-air equipmentCompatible Fresh-Air EquipmentFresh-Air Unit · ERV · HRV
MAXMAC motorized air distribution boxMAXMAC Motorized Air Distribution BoxDirects supply air to individual rooms
MAXMAC master and slave IAQ ventilation controllersMaster / Slave IAQ ControllersMonitor rooms and coordinate ventilation demand
High-demand living room ventilation zone
Living room damper at full airflow
Living RoomHigh IAQ Demand100% Airflow
Living room IAQ controller
Master bedroom ventilation zone
Master bedroom damper at 70 percent airflow
Master BedroomModerate IAQ Demand60–70% Airflow
Master bedroom IAQ controller
Children's room ventilation zone
Children's room damper at 30 percent airflow
Children’s RoomLow IAQ Demand30–40% Airflow
Children's room IAQ controller
Study ventilation zone
Study damper at minimum airflow
StudyIAQ Within TargetConfigured Minimum Ventilation
Study IAQ controller

WHOLE-HOME DCV ARCHITECTURE

How the MAXMAC Whole-Home Demand-Controlled Ventilation System Works

The MAXMAC whole-home DCV architecture connects room controllers with integrated IAQ sensing to a master control interface, fresh-air equipment and motorized zone dampers. Each room reports its own air quality conditions, allowing the system to coordinate ventilation demand and airflow independently across the home.

01

Room-Level IAQ Monitoring

Integrated controllers monitor the air where occupants actually live.

02

Centralized Ventilation Coordination

The master controller makes every room’s IAQ status and ventilation demand visible from one interface.

03

Independent Zoned Air Delivery

Each motorized damper regulates fresh-air delivery according to its room’s actual demand.

MAXMAC plenum box
Plenum Box
MAXMAC A70 plug-in motorized zone damper
A70 Motorized Zone Damper

MODULAR ZONED AIR DISTRIBUTION

Combine the Plenum Box with Plug-In Motorized Zone Dampers

MAXMAC’s motorized zone damper can plug directly into the compatible plenum box, creating a compact and modular air-distribution assembly for whole-home demand-controlled ventilation.

Each connected damper independently regulates airflow to its assigned room. This allows the system to expand by zone, simplifies installation and helps deliver fresh air precisely where real-time indoor air quality data indicates it is needed.

Discuss Your Zoned Airflow Project

IAQ-BASED FRESH-AIR CONTROL

Reduce Unnecessary Whole-Home Ventilation with Room-Level IAQ Data

Traditional ventilation systems often rely on fixed schedules or air quality measurements collected from a central duct. These measurements cannot accurately represent the conditions of every room and may cause the entire home to be ventilated when only one area requires fresh air.

MAXMAC integrates multi-parameter IAQ sensing directly into room controllers, allowing the system to monitor PM2.5, CO₂, TVOC, temperature and humidity where occupants actually live. When air quality deteriorates in one room, the fresh-air system can respond specifically to that room while maintaining the minimum airflow configured for other rooms.

By reducing unnecessary airflow, the system also helps reduce the energy used to filter, heat or cool incoming outdoor air.

Room-Level IAQ MonitoringVentilation Only When NeededReduced Fresh-Air TreatmentLower Energy Use and Emissions

Design Resources

Explore Integration Guides

Use the relevant guide when reviewing the sensing, control or installation choices for this solution.

Discuss Your Zoned Ventilation Project

Share the room layout, fresh-air equipment and minimum ventilation requirements. We can help you review sensing, controls and zoned delivery.