MAXMAC wireless thermostat for connected HVAC and IAQ control

Wireless Thermostat OEM/ODM Manufacturer

Smart Wireless Thermostat Manufacturer & OEM Supplier with Integrated Multi-Sensor IAQ Platform

As a professional HVAC control and sensing solutions provider, MAXMAC supplies next-generation smart wireless thermostat solutions to B2B customers and engineering partners worldwide. More than an efficient wireless smart thermostat, each product integrates the MAXMAC multi-in-one air quality sensor platform for real-time monitoring of PM2.5, CO₂, TVOC, temperature and humidity. One device enables unified wireless smart control of air conditioning, fresh-air ventilation, underfloor heating and fragrance systems throughout the home.

Production operates under strict ISO 9001 and IATF 16949 quality management systems, and our manufacturing base houses a national CNAS-accredited standard laboratory for environmental simulation, aging and consistency testing from the earliest stages of product development. All MAXMAC thermostat products fully comply with CE and RoHS requirements. We provide reliable, high-performance OEM/ODM solutions that help customers lead the smart environmental control market.

WIRELESS THERMOSTAT SERIES

Explore Our Next-Gen Wireless Programmable Thermostat Series: Multi-System vs. Dedicated Ventilation Control

6-A6314-K wireless room thermostat
6-A6314-K

6-A6314-K Wireless Room Thermostat

Hardware
4-inch full-color touchscreen · 12V 1A
Connectivity
Wireless + Wired - WiFi + RS485 | Modbus / RF / Zigbee / Ethernet expandable
Built-in Sensors
Temperature + Humidity

The 6-A6314-K is a premium wireless room thermostat with a 4-inch full-color touchscreen and integrated high-precision temperature and humidity sensing. Dual-mode WiFi cloud control and wired RS485 communication can be expanded with Modbus, RF, Zigbee and Ethernet. As a whole-home control hub, this modern thermostat coordinates air conditioning, fresh-air ventilation, underfloor heating and fragrance systems from one interface.

Read more
6-A6315-K wireless smart thermostat
6-A6315-K

6-A6315-K Wireless Smart Thermostat

Hardware
4-inch full-color touchscreen · 12V 1A
Connectivity
Wireless + Wired - WiFi + RS485 | Modbus / RF / Zigbee / Ethernet expandable
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5 + TVOC

The 6-A6315-K is a flagship wireless smart thermostat with a 4-inch touchscreen and a complete IAQ sensor suite for real-time monitoring of PM2.5, CO₂, TVOC, temperature and humidity. One device integrates control of air conditioning, fresh-air ventilation, underfloor heating and fragrance systems, making it one of the best wireless thermostat options for projects that prioritize both indoor air quality and comfort. Modbus, RF, Zigbee and Ethernet expansion is available.

Read more
6-A2302-H large screen thermostat with wireless remote sensor
6-A2302-H

6-A2302-H Large Screen Thermostat with Wireless Remote Sensor

Hardware
6-inch full-color touchscreen · 12V 1A
Connectivity
Wireless + Wired - WiFi + RS485 | Modbus / RF / Zigbee / Ethernet expandable
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5 + TVOC

The 6-A2302-H is a premium thermostat with wireless remote sensor support, pairing a luxurious 6-inch full-color touchscreen with a complete onboard IAQ sensor suite. Its WiFi/RS485 dual-mode connectivity enables centralized control of air conditioning, fresh-air ventilation, underfloor heating and fragrance systems. This modern thermostat is designed for premium apartments and villa projects, with Modbus, RF, Zigbee and Ethernet expansion available.

Read more
6-A561-K portable desktop wireless thermostat sensor
6-A561-K (Desktop)

6-A561-K Portable Desktop Wireless Thermostat Sensor

Hardware
4-inch full-color touchscreen · 3000mAh lithium battery
Connectivity
Wireless - WiFi | Modbus / RF / Zigbee / Ethernet expandable
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5 + TVOC

Powered by a 3000mAh lithium battery, the 6-A561-K is a truly portable desktop wireless thermostat sensor that can measure the indoor environment wherever it is placed without complex wiring. Through WiFi, this wireless smart thermostat sensor remotely coordinates air conditioning, underfloor heating, fresh-air ventilation and fragrance equipment for flexible comfort control. Modbus, RF, Zigbee and Ethernet expansion is available.

FLEXIBLE COMMUNICATION

Custom Wireless Thermostat and Receiver Connectivity

MAXMAC smart thermostats can be customized with RS485, WiFi, Zigbee, Ethernet and RF communication protocols to match different HVAC, boiler and smart-home integration requirements.

Bright modern home prepared for wireless thermostat installation across air conditioning, fresh-air ventilation, underfloor heating and fragrance systems MAXMAC wireless thermostat controller GatewayMAXMAC smart gateway ReceiverWireless thermostat RF receiver SmartphoneSmartphone with wireless thermostat controls
01

RF Boiler Control

Configured as a wireless thermostat transmitter, the smart thermostat sends control signals to a matched receiver over RF. The receiver then switches and regulates the connected boiler without requiring a direct control cable between the thermostat and heating equipment.

02

Zigbee & System Integration

Zigbee connectivity enables integration with compatible smart-home devices, fresh-air ventilation and air-conditioning systems. RS485 and Ethernet options are also available for reliable wired communication with HVAC equipment and building-control platforms.

03

WiFi Room-Level IAQ Monitoring

WiFi connects the thermostat to a smartphone, allowing users to view room-level indoor air quality and environmental data in real time, including PM2.5, CO₂, TVOC, temperature and humidity when the corresponding sensors are configured.

Discuss Your Wireless Thermostat Project

SMART HEATING & COOLING CONTROL LOGIC

Smart Wireless Thermostat Setting for Optimized Heating & Cooling Control

Intelligent wireless control begins with precise awareness of the indoor environment. An integrated high-precision wireless thermostat sensor continuously tracks temperature, humidity and configured air-quality conditions, while the app gives users direct access to comfort targets and operating preferences.

Based on real-time changes and the selected wireless thermostat setting, the smart thermostat sends control commands over WiFi, RF or RS485 to coordinate air conditioning, boilers, energy-recovery ventilation and fragrance systems. Each connected device responds as needed to optimize comfort, indoor air quality and energy efficiency.

  • Wireless Sensor / App Monitors conditions and comfort settings
  • Wireless Smart Thermostat Analyzes data and selects the response
  • HVAC Systems Controls AC, boiler, ERV and fragrance
  • Indoor Climate Optimization Balances comfort, air quality and efficiency

Product Architecture & Multi-Sensor Integration

Integrated Wireless Thermostat Sensor Architecture & Onboard Multi-Sensor Platform

Unlike conventional devices that rely on external probes or a single temperature-sensing element, MAXMAC uses a highly integrated onboard design that embeds an advanced wireless thermostat sensor module directly into the thermostat main PCB and engineered enclosure. This architecture delivers exceptionally precise, real-time sensing of the indoor environment.

Exploded MAXMAC wireless thermostat showing the display, PCB, onboard multi-sensor platform and engineered enclosure
1

4-Inch 480 × 480 dpi Full-Color Capacitive LCD Touchscreen

5

M4 Screw Fastening

2

PC+ABS, UL 94 HB Flame-Retardant Housing

3

MAXMAC IAQ Multi-Sensor (PM + CO₂ + Temperature & Humidity + Expandable TVOC)

4

Dual RS485, Modbus-Compatible, Optional WiFi

Customize Your Wireless Thermostat

KEY SENSOR ENGINEERING

MAXMAC IAQ multi-sensor development board for onboard wireless thermostat integration

Direct PCB Onboard Integration

1

High-Precision Sensor Array

Digital temperature, humidity, CO₂, PM2.5 and TVOC sensing elements and compact modules are integrated directly with the main control PCB to form a space-efficient, multi-in-one wireless thermostat sensor platform. Eliminating complex external probe wiring simplifies installation and helps keep the wall finish clean and uncluttered.

Explore Multi-Sensor Modules
Wireless thermostat enclosure airflow and sensor sampling cavity design

Thermal Isolation & Structural Ventilation

2

Precision Airflow Cavity

Purpose-designed convection openings along the side and bottom of the enclosure allow room air to flow naturally through the internal wireless thermostat sensor sampling zone. The structured airflow cavity helps isolate sensing from heat generated by internal electronics, supporting a faster response and more representative room measurements.

Multi-point wireless thermostat sensor factory calibration curve

Factory Calibration & Real-Time Data Calibration

3

Multi-Point Factory Calibration

Every integrated wireless thermostat sensor module is calibrated in high-precision temperature, humidity and gas calibration chambers before shipment to ensure consistent environmental data acquisition. Built-in anti-drift algorithms and ABC (Automatic Baseline Calibration) maintain stable, high-accuracy output during long-term indoor operation, supporting a design target of up to 15 years of maintenance-free operation.

THERMOSTAT PRODUCT INFORMATION

Integrated Sensor Specifications and Package Contents for Wireless Thermostats

Built-in Sensor Specifications

Measurement Operating Principle Range Resolution Accuracy
PM2.5Laser scattering0–999 μg/m³1 μg/m³±15 μg/m³ at ≤100; ±15% above 100
CO₂NDIR infrared400–9999 ppm1 ppm±(50 ppm + 5% of reading)
TemperatureCMOSens®−20°C to 85°C1°C±2°C
HumidityCMOSens®1–99% RH1% RH±5% RH
TVOCSemiconductor conductivity1–30,000 ppb1 ppb—

Package Contents

ItemDescriptionQuantity
1Pearl-cotton protective separator1
2Installation manual, certificate and warranty card1
3Integrated IAQ thermostat controller1
4Pearl-cotton inner tray1
5M4 × 30 mm mounting screws2
64-pin wiring terminal1
72-pin wiring terminal1
8Outer carton1
9Outer-carton label1
Exploded view of MAXMAC wireless thermostat package contents

THERMOSTAT INSTALLATION GUIDE

Wireless Thermostat Installation & Setup Guide

1Separating the thermostat front frame from the rear cover assembly
STEP A

Separate the Front and Rear Assemblies

Insert a flat-head screwdriver into the separation slot on the bottom or lower side. Support the front frame with one hand to protect the LCD and prevent it from falling, then gently pry and slowly lift the front frame to separate the front and rear assemblies.

2Thermostat power and communication terminal wiring definitions
STEP B

Complete Power and Communication Wiring

Following the controller wiring definitions, connect the power cable and communication lines to the specified terminals in sequence.

3Mounting the thermostat rear assembly in a wall box with the sensor sampling port facing down
STEP C

Mount the Rear Assembly in the Wall Box

Place the controller rear assembly in an 86-type wall box with the sensor sampling port facing downward. Ensure the wall surface is flat, then secure the assembly with screws.

4Snapping the thermostat front frame securely onto the rear assembly
STEP D

Snap the Front Assembly into Place and Commission

Snap the front frame securely onto the rear assembly and switch on the power. After the LCD illuminates, proceed with commissioning of the controlled equipment.

Installation Requirements

  1. This product must be installed by a qualified professional. Improper installation may damage the equipment.
  2. Verify that the control panel supply voltage and power rating meet the operating requirements.
  3. Install the control panel approximately 1.5 meters above the floor in a well-ventilated location.

Do Not Install in the Following Locations

  • Poorly ventilated locations, including corners and behind doors.
  • Near heating or cooling pipes, direct sunlight or other heat sources.
  • Locations with unusually low or high indoor temperatures, including walls in direct contact with the outdoors.
Diagram showing unsuitable thermostat installation locations behind a door and in an unventilated corner

INTUITIVE MULTI-SYSTEM CONTROL

Wireless Thermostat Control: Precision HVAC Multi-System Integration

The main interface brings together air quality monitoring, fresh-air ventilation, fragrance, air conditioning and underfloor heating. Swipe left or right to move between function pages and operate the connected equipment. Available screens may vary according to the devices connected and the requirements of each project.

Wireless thermostat air quality monitoring interface showing carbon dioxide, PM2.5, temperature and humidity
Air Quality
Wireless thermostat fresh-air ventilation control interface
Fresh Air Ventilation
Wireless thermostat fragrance system control interface
Fragrance System
Wireless thermostat air-conditioning control interface
Air Conditioning
Wireless thermostat underfloor heating control interface
Underfloor Heating

Select the settings icon in the lower-left corner of the home screen to open the settings page.

Select the power icon in the lower-right corner to switch the corresponding equipment on or off. A highlighted icon indicates that the equipment is on; a dimmed icon indicates that it is off.

Open the main settings screen and select the corresponding icon to access each settings page. Use Time Settings to set the system clock, Backlight Settings to adjust LCD brightness and screen-on duration, and About to view the software version. Select More to open Engineering Configuration. This function is intended exclusively for commissioning by qualified professionals.

Wireless thermostat main settings interface with time, backlight, more and about options
Wireless thermostat system time settings interface
Wireless thermostat LCD brightness and screen-on duration settings interface

Underfloor Heating Control

The underfloor heating home screen displays the current room temperature and target temperature. Select the icon outside the temperature ring to adjust the operating settings. If the i fault icon appears, communication with the underfloor heating equipment is abnormal.

Underfloor heating home screen showing room temperature and target temperature
Underfloor heating target temperature adjustment interface

Set the Underfloor Heating Target Temperature

Fresh Air Ventilation Control

The fresh-air home screen displays the current indoor CO₂ and PM2.5 readings. Select the icons outside the ring to adjust the operating settings. If the i fault icon appears, communication with the connected fresh-air equipment is abnormal.

Fresh-air ventilation home screen showing carbon dioxide and PM2.5 readings
Ventilation operating mode icon Fresh-air ventilation operating mode selection interface
  • Smart Auto: Automatically adjusts airflow according to indoor air quality.
  • Standard Ventilation: Exchanges indoor and outdoor air directly without heat recovery.
  • Energy-Saving Fresh Air: Uses heat recovery to balance ventilation and energy efficiency.
  • Recirculation Purification: Filters recirculated indoor air without introducing outdoor air.
Fresh-air fan speed icon Fresh-air ventilation fan speed adjustment interface
  • Drag the slider to set the fan speed. In Smart Auto mode, the fan speed changes automatically.
Fresh-air zone control icon Fresh-air ventilation zone control interface
  • Zone control becomes available after the motorized air valves for each supply-air zone have been configured.
  • During installation, each air valve must use a unique RS485 address.

Fresh Air Ventilation Control — Zone Control

Zone control distributes airflow by adjusting the opening of the motorized air valve in each zone together with the total airflow supplied by the fresh-air unit. The system provides three operating modes. Both Smart and Manual modes allow unused zone valves to be switched off.

Smart Mode: Uses air-quality data and an intelligent algorithm to adjust the opening of each connected zone valve automatically.

Standard Mode: Opens each valve to the position defined during project commissioning; valve opening cannot be adjusted from this screen.

Manual Mode: Allows the user to adjust the opening of each zone valve independently.

Valve opening is adjustable from 0% to 100% (0% fully closed and 100% fully open) in 5% increments.

Smart mode fresh-air zone control interface
Standard mode fresh-air zone control interface
Manual mode fresh-air zone control interface

Air Conditioning Control

The air-conditioning home screen displays the current temperature and target temperature for the selected zone. Select the icons outside the temperature ring to adjust the operating settings. If the i fault icon appears, communication with the connected air-conditioning equipment is abnormal.

Air-conditioning home screen showing current and target zone temperature
Air-conditioning zone selection icon Air-conditioning zone selection interface

Switch the active air-supply zone to adjust the temperature and fan speed for that zone.

Air-conditioning operating mode icon Air-conditioning operating mode selection interface

Set the air-conditioning operating mode. This is a system-wide setting and applies to every zone.

Air-conditioning fan speed icon Air-conditioning fan speed selection interface

Set the air-conditioning fan speed for the selected zone.

Air-conditioning target temperature icon Air-conditioning target temperature adjustment interface

Set the target operating temperature for the selected zone.

Fragrance Control

The fragrance home screen displays the active fragrance and remaining cartridge level. Select the icons outside the fragrance ring to configure fragrance type, intensity and operating schedule. If the i fault icon appears, communication is abnormal or the fragrance cartridge has not been recognized. Replace the cartridge when the remaining level reaches 0%.

Fragrance control home screen showing active fragrance and remaining cartridge level
Fragrance type selection icon Fragrance type selection interface

Switch the active fragrance. The highlighted fragrance is active; this option applies to connected dual-channel fragrance generators.

Fragrance intensity icon Fragrance intensity selection interface

Set the fragrance intensity. Compatible single-channel equipment supports low and high output levels.

Fragrance schedule icon Fragrance timing and intermittent operation settings interface

Schedule the start time, set the operating duration for automatic shutdown, and configure the fragrance release and pause cycle for intermittent operation.

Explore Our Whole-Home Smart Fragrance Products

Engineering Configuration

Engineering Configuration is used to set device parameters and commission the controller’s RS485 network. It includes master and secondary controller panel configuration, device address assignment, zone binding and motorized air-valve zero-position calibration. This area is intended exclusively for qualified commissioning engineers and requires password verification.

Open Engineering Configuration to access detailed parameter settings. After zone air-valve configuration has been enabled, the master controller can display the opening of each motorized valve and the zone-binding list for supply-air and return-air distribution boxes. If no zone name appears in the list, the valve is not assigned to a zone and does not participate in airflow distribution.

Engineering configuration main interface
Supply-air motorized valve opening configuration interface
Return-air motorized valve opening configuration interface

If the complete list is not visible, swipe up or down to view the remaining items.

Master/Slave Setup

Select Master/Secondary Setup from Engineering Configuration to define the controller role and assign its network address.

MasterSet this controller as the master control panel and enter the number n of secondary control panels connected to it. The master then recognizes secondary-panel addresses from 48 through 47+n.

SlaveSet this controller as a secondary control panel and assign its address within the range 48 through 47+n. The corresponding panels are identified as Secondary Panel 1 through Secondary Panel n.

Engineering configuration menu interface
Master controller setup interface
Secondary controller setup interface

Recommended configuration order: Master/Secondary Setup → Local Controlled Devices → Zone Configuration (Zone Configuration → Supply-Air Motorized Distribution Box → Supply-Air Motorized Valve Setup).

Local Control Devices

Local Controlled Devices defines which fresh-air ventilation, air-conditioning, underfloor heating and fragrance equipment can be controlled from this panel. The selected configuration determines whether the corresponding function pages appear on the home interface.

Local controlled devices engineering configuration interface

Zone Smart Control Set Up

Zone Configuration is used to enable or disable individual zones, assign zone names and associate each zone with its controller panel.

After a motorized air distribution box is enabled, its connected air valves can be assigned to the corresponding terminal zones or left unassigned. The opening percentage of each valve can also be configured under standard operating conditions. The setup procedure is the same for supply-air and return-air motorized distribution boxes and their corresponding valves.

Zone smart control configuration interface for supply-air and return-air motorized distribution boxes

Zone Configuration

The Zone Configuration interface uses Enabled and Disabled to control each zone, assign its name and bind it to the appropriate controller panel. When the same zone name is used for multiple areas, add a numeric suffix x so each area is identified as Name_x, for example, Aisle_1.

Zone binding can be configured only from the Master controller. By default, the master controller is bound to Zone 1, with the zone set to Enabled. Installing the master controller in a shared area is recommended for easier system management. The controller-panel list is generated dynamically according to the number of secondary controllers defined in the master/secondary configuration.

— indicates that an enabled zone has not yet been given a zone name or assigned to a secondary controller. Every enabled zone must be named; a zone without its own controller panel can remain unbound.

Zone enablement, naming and controller-panel binding interface
Zone name selection and numeric suffix configuration interface
Zone controller-panel binding selection interface

Air Distribution Box & Motorized Air Valve Configuration

When an air valve is set to Enabled, bind the terminal zone name for the duct connected to that valve. When it is set to Disabled, neither a zone name nor a valve-opening percentage can be assigned.

The zone-binding list for each air valve displays only the zone names that have been enabled in Zone Configuration.

— indicates that the terminal connected to an enabled valve has not been bound to a zone. The valve configuration becomes valid and its opening can be adjusted only after the zone is assigned.

Zone 9: — indicates that the connected terminal zone is enabled but has not been given a zone name. Correct the zone name and binding before commissioning.

After configuring the motorized valve opening, select New Air Valve Test to open the test screen, start the fresh-air system and verify the valve’s operation. Save the configuration for the new opening values to take effect.

Supply-air motorized distribution box valve enablement and zone configuration interface
Supply-air motorized valve zone-binding interface
Supply-air motorized valve opening-percentage configuration interface
New air valve test interface with fresh-air speed selection

WHY CHOOSE US

Why Choose MAXMAC: Pioneer in Integrated Sensor Thermostat Manufacturing

Backed by in-house engineering, testing and manufacturing capabilities, MAXMAC goes beyond the limits of conventional HVAC controllers. Integrating multi-in-one air quality sensing—including PM2.5, CO₂, TVOC, temperature and humidity—directly into a thermostat control board is not a simple matter of combining modules. It requires deep technical expertise and proven manufacturing capability. These two core advantages make MAXMAC a preferred smart thermostat partner for global OEM and ODM customers.

01

Deep Gas & IAQ Sensing Expertise

We do not simply purchase sensor assemblies and combine them with a controller. Years of in-house gas-sensor development have given MAXMAC a strong Sensor DNA. From optical NDIR algorithms and MOS semiconductor processes to complex temperature and humidity compensation, our engineers understand sensing technology at its foundation. This expertise allows us to integrate sensor circuitry closely with the thermostat main control board, address signal interference and thermal drift, and create an elegant modern thermostat that delivers accurate, stable air quality measurements over the long term.

02

In-House SMT & Rapid PCB Prototyping

Our in-house SMT production lines and engineering R&D team support the complete process from PCB design and interface customization to structural development. For individualized B2B OEM and ODM requirements, we provide rapid prototyping and efficient sample iteration. A fully controlled manufacturing chain gives us the flexibility to support both small pilot runs and high-volume delivery while offering cost-effective WiFi thermostat solutions that help customers significantly shorten time to market.

03

Flexible Thermostat Production with Full MES Traceability

MAXMAC combines automated production lines with manual assembly lines, allowing us to switch production methods flexibly according to thermostat structure, order volume and customer-specific requirements. This approach provides an efficient solution for thermostat manufacturing. Automated equipment safeguards consistency and delivery efficiency in volume production, while manual workstations support complex assembly, small-batch pilot runs and customized thermostat manufacturing.

At the same time, every production stage is connected to our MES system, enabling full MES traceability across material batches, PCB assembly, firmware programming, sensor calibration and finished thermostat inspection. This complete data trail gives customers more dependable quality-management assurance and supports reliable OEM/ODM thermostat volume delivery.

TESTING & VALIDATION

CNAS-Accredited Laboratory

MAXMAC’s CNAS-accredited laboratory brings product verification closer to our engineering and manufacturing teams, significantly shortening validation cycles and accelerating the transition from design to volume production. By identifying design weaknesses, potential failure modes, and risk-control points at an early stage, our laboratory capabilities help prevent issues before they reach customers or enter mass production.

Comprehensive mechanical, electrical, environmental, gas, and microbiological testing enables us to verify product performance under demanding operating conditions. This evidence-based validation process strengthens product stability, long-term reliability, and quality consistency while giving OEM/ODM customers greater confidence throughout development and delivery.

CNAS accreditation logo

Specialized Laboratory Facilities

  • Mechanical Reliability Testing Laboratory
  • Electrical Performance Testing Laboratory
  • Bacterial Culture Laboratory
  • Microbiological Testing Laboratory
  • Gas Testing Laboratory
  • Microbiological Inspection Laboratory
  • Balance Room
  • Precision Instrument Room
  • Ventilation Ducts Room
  • High Temperature Testing Laboratory
  • Product Aging Testing Laboratory
  • Impact Testing Laboratory
  • Salt Spray Testing Laboratory
  • Cold Chamber Laboratory
  • Vibration Testing Laboratory
Explore Our CNAS Laboratory
QUALIFICATION CERTIFICATES

Certifications and Quality Management

As a professional manufacturer of thermostats and HVAC controllers, our products come with a wide range of certifications and test reports to ensure quality, safety, and performance. These include ISO 14001, ISO 45001, ISO 9001, IATF 16949, CNAS laboratory accreditation, and more. These certifications reflect our commitment to delivering reliable thermostat and HVAC control solutions that meet global standards.

ISO 14001 Certificate
ISO 14001 Certificate
ISO 45001 Certificate
ISO 45001 Certificate
ISO 9001 Certificate
ISO 9001 Certificate
IATF 16949 Certificate
IATF 16949 Certificate
CNAS Laboratory Accreditation
CNAS Laboratory Accreditation
CNAS Laboratory Accreditation Certificate
CNAS Laboratory Accreditation Certificate

TRUSTED PARTNERS

Trusted Customers

MAXMAC supports established HVAC, thermal-management and building-technology companies with integrated sensing, thermostat controller development and OEM/ODM manufacturing services.

From product definition and PCB engineering to validation and volume delivery, our teams work closely with customers to bring reliable, connected climate-control products to market.

HVAC Brands Thermal Management OEM/ODM Partners
Carrier logo Valeo logo DENSO logo Hisense logo Honeywell logo HITACHI logo Panasonic logo YENOVA logo Habit@ logo MAHLE logo
FAQS

Frequently Asked Questions About Wireless Thermostats

Why use a wireless thermostat for smart indoor climate control?

Compared with a conventional wired control panel, a wireless smart thermostat reduces the need to open walls, route long control cables or carry out complex installation work. It can be positioned where it can measure representative room conditions, while mobile-app access enables convenient remote control. When configured with indoor air quality sensing, the thermostat can also coordinate connected HVAC equipment according to temperature and IAQ data, helping improve comfort and reduce unnecessary energy use. For customers asking why use a wireless thermostat, flexible placement, easier installation and connected HVAC control are the principal benefits.

Can MAXMAC devices be used as a wireless thermostat for furnace or boiler systems?

Yes. Compatible MAXMAC controllers can be configured with dry-contact and standard signal outputs for use as a wireless thermostat for furnace applications or a wireless thermostat for boiler control. Depending on the selected model and project configuration, the thermostat can interface with forced-air furnaces, wall-hung boilers and hydronic underfloor-heating systems while also coordinating central air conditioning and fresh-air ventilation. The MAXMAC platform reserves the necessary hardware interface capacity and configurable software control points for third-party equipment integration. Once the equipment brand provides its communication protocol and interface definitions,our engineering team can begin protocol mapping and system integration. The final equipment interface, control voltage and receiver configuration are confirmed during project engineering.

What should I check if my wireless heating thermostat or boiler thermostat is not working properly?

If a wireless heating thermostat stops responding, or when troubleshooting a boiler thermostat not working issue, first check that the power terminals are secure and that the supply voltage matches the rating specified for the selected model. Next, verify the WiFi, RF or RS485 communication status and confirm that the dry-contact or control-signal output is triggering the heating equipment correctly. If the communication link has dropped, follow the model-specific instructions to pair or reset the thermostat. Electrical wiring and mains-powered equipment should be inspected by a qualified technician.

How complex is a home thermostat replacement with MAXMAC wireless smart thermostats?

A home thermostat replacement can be straightforward when the existing HVAC interface, supply voltage and wiring are compatible with the selected MAXMAC controller or receiver. WiFi communication and standardized terminal definitions can simplify the replacement of an older mechanical or wired thermostat while adding more precise temperature control, remote access and indoor air quality monitoring. A qualified installer should confirm compatibility and complete any required electrical work before commissioning.

What is the Minimum Order Quantity (MOQ) for B2B procurement?

Our standard Minimum Order Quantity (MOQ) for B2B wireless thermostat procurement and volume orders is 1,000 units. Before bulk production, sample units can be supplied for engineering evaluation, functional testing and project approval. Final pricing and production lead time are confirmed according to the selected specifications, customization scope and order quantity.

Do you support customization (OEM/ODM) services for bulk orders?

Yes. MAXMAC provides complete OEM/ODM customization for B2B bulk orders and private-label projects. Available options include enclosure colors, logo printing, user-interface design, sensor configurations, communication protocols such as WiFi, RS485 and Modbus, software control logic, packaging and labeling. Our engineering team can evaluate project requirements and develop a customized wireless thermostat platform for volume production.

Provide Your Details for Professional Product Consultation

Our product experts will provide the most suitable air solutions and product recommendations.