MAXMAC wired thermostat with integrated multi-sensor indoor air quality monitoring

WIRED THERMOSTATS

Smart Wired Thermostats Manufacturer & OEM Supplier with Integrated Multi-Sensor IAQ Platform

As a professional HVAC control and sensing solutions provider, MAXMAC supplies digital wired thermostat solutions for residential, hotel and commercial HVAC projects. Each product integrates MAXMAC’s multi-in-one air quality sensor platform for real-time monitoring of PM2.5, CO₂, TVOC, temperature and humidity, helping customers build stable room-level control panels for their HVAC systems.

OEM/ODM customers can customize hardware, UI, control logic, sensor configuration and communication protocols according to project requirements. Production operates under strict ISO 9001 and IATF 16949 quality management systems, and our manufacturing base houses a national CNAS-accredited laboratory for environmental simulation, aging and consistency testing from the earliest stages of product development. All MAXMAC thermostat products are designed to comply with CE and RoHS requirements.

WIRED THERMOSTAT SERIES

Explore Our Next-Gen Digital Wired Thermostat Series

6-A6312-K wired digital thermostat
6-A6312-K

6-A6312-K Wired Digital Thermostat

Hardware
4-inch full-color touchscreen · 12 V / 1 A
Connectivity
Wired · RS485 · Modbus / Ethernet expandable · No WiFi
Built-in Sensors
Temperature + Humidity

The 6-A6312-K is a wired digital thermostat built around stable RS485 bus communication. It features a 4-inch full-color touchscreen and integrated temperature and humidity sensors, making it suitable for wired HVAC, underfloor heating and fan coil control projects. For customers evaluating wired thermostats for underfloor heating, the controller provides reliable room-level temperature regulation while supporting unified operation of connected indoor comfort systems from one wall-mounted interface.

Read more
6-A6316-K wired digital thermostat
6-A6316-K

6-A6316-K Wired Digital Thermostat

Hardware
4-inch full-color touchscreen · 12 V / 1 A
Connectivity
Wired · RS485 · Modbus / Ethernet expandable · No WiFi
Built-in Sensors
Temperature + Humidity

The 6-A6316-K is a wired 4-inch thermostat with built-in temperature and humidity sensing. Designed for projects that require fixed RS485 communication without WiFi, it can support room-level HVAC control, fan coil control and underfloor heating control through a clear touchscreen interface. The model is suitable for projects where local wired stability is more important than cloud connectivity.

Read more
6-A6314-K WiFi and RS485 thermostat
6-A6314-K

6-A6314-K WiFi + RS485 Thermostat

Hardware
4-inch full-color touchscreen · 12 V / 1 A
Connectivity
WiFi + RS485 · Modbus / Ethernet / RF / Zigbee expandable
Built-in Sensors
Temperature + Humidity

The 6-A6314-K combines WiFi cloud connectivity with wired RS485 bus communication. It includes built-in temperature and humidity sensors, allowing the thermostat to support both local room control and remote access. Among MAXMAC connected thermostats, this model is suitable for projects where users need app-based operation while still keeping RS485 communication for HVAC, underfloor heating, fresh-air ventilation or fan coil integration.

Read more
6-A6313-K wired programmable thermostat
6-A6313-K

6-A6313-K Wired Programmable Thermostat

Hardware
4-inch full-color touchscreen · 12 V / 1 A
Connectivity
Wired · RS485 · Modbus / Ethernet expandable · No WiFi
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A6313-K is one of MAXMAC’s wired programmable thermostats with built-in temperature, humidity, CO₂ and PM2.5 sensors. It supports scheduled HVAC control while monitoring indoor comfort and air quality from the same wall panel. With stable RS485 communication, this model is suitable for projects that need wired system control, programmable operation and real-time IAQ data without relying on WiFi.

Read more
6-A6310-K wired IAQ thermostat
6-A6310-K

6-A6310-K Wired IAQ Thermostat

Hardware
4-inch full-color touchscreen · 12 V / 1 A
Connectivity
Wired · RS485 · Modbus / Ethernet expandable · No WiFi
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A6310-K is a wired IAQ thermostat with integrated temperature, humidity, CO₂ and PM2.5 sensors. It is designed for wired HVAC and room-control projects that need both equipment control and indoor environmental monitoring. Through RS485 communication, one controller can coordinate heating, cooling, ventilation or fan coil systems while providing real-time air quality feedback.

Read more
6-A6307-K wired IAQ thermostat
6-A6307-K

6-A6307-K Wired IAQ Thermostat

Hardware
4-inch full-color touchscreen · 12 V / 1 A
Connectivity
Wired · RS485 · Modbus / Ethernet expandable · No WiFi
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A6307-K is a 4-inch wired thermostat with built-in temperature, humidity, CO₂ and PM2.5 sensing. It is suitable for projects that want a fixed RS485 control panel with IAQ monitoring inside the thermostat. The model can be used for apartments, offices, hotels and smart-building projects where stable wired communication and indoor air quality data are both required.

Read more
6-A6315-K WiFi and RS485 programmable thermostat
6-A6315-K

6-A6315-K WiFi + RS485 Programmable Thermostat

Hardware
4-inch full-color touchscreen · 12 V / 1 A
Connectivity
WiFi + RS485 · Modbus / RF / Zigbee / Ethernet expandable
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A6315-K is a programmable thermostat with WiFi and RS485 communication, plus built-in temperature, humidity, CO₂ and PM2.5 sensors. It supports remote access, local wired control and scheduled operation from one device. This model is suitable for smart wired thermostat projects that need both app control and reliable RS485 integration for HVAC, underfloor heating, fresh-air ventilation or fan coil systems.

Read more
6-A2301-H large-screen wired thermostat
6-A2301-H

6-A2301-H Large-Screen Wired Thermostat

Hardware
6-inch full-color touchscreen · 12 V / 1 A
Connectivity
Wired · RS485 · Modbus / Ethernet expandable · No WiFi
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A2301-H is a large-screen wired thermostat with built-in temperature, humidity, CO₂ and PM2.5 sensors. Its 6-inch touchscreen provides more space for system status, control pages and indoor environmental data. With RS485 communication and no built-in WiFi, it is suitable for high-end residential, hotel and commercial HVAC projects that require stable wired control.

Read more
6-A2302-H 6-inch WiFi and RS485 thermostat
6-A2302-H

6-A2302-H 6-Inch WiFi + RS485 Thermostat

Hardware
6-inch full-color touchscreen · 12 V / 1 A
Connectivity
WiFi + RS485 · Modbus / RF / Zigbee / Ethernet expandable
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A2302-H is a 6-inch touchscreen thermostat with WiFi and RS485 communication. It integrates temperature, humidity, CO₂ and PM2.5 sensors inside the controller, supporting both indoor air quality monitoring and HVAC control from one large interface. It is suitable for premium projects that need remote access, wired system integration and a larger display for multi-system operation.

Read more
6-A5601-K desktop WiFi and RS485 thermostat
6-A5601-K

6-A5601-K Desktop WiFi + RS485 Thermostat

Hardware
4-inch full-color touchscreen · 3000 mAh lithium battery
Connectivity
WiFi + RS485 · Modbus not supported · Ethernet not supported
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A5601-K is a desktop thermostat with built-in temperature, humidity, CO₂ and PM2.5 sensors. Powered by a 3000 mAh lithium battery, it supports flexible placement while keeping WiFi and RS485 communication available. This model is suitable for projects that need a movable control terminal for indoor comfort monitoring, air quality display and connected HVAC operation.

Read more

WIRED HVAC & MULTI-SYSTEM CONTROL

One Wired Thermostat for Stable HVAC and Indoor Comfort System Integration

MAXMAC wired thermostats bring room-level HVAC control and indoor environmental management together. From one touchscreen interface, users can operate connected air-conditioning, fresh-air ventilation, underfloor heating and fragrance systems while viewing real-time temperature, humidity and optional indoor air quality data.

Each control branch can be configured around the connected equipment, required operating modes and approved project logic. RS485 device addressing allows multiple controllers and HVAC devices to communicate across the same wired network, while optional Modbus and Ethernet expansion support integration with building-management and smart-home systems.

MAXMAC wired thermostat coordinating five indoor control branches

Air Conditioning

Mode, temperature, fan speed and zone control

Select the active air-conditioning zone and configure its operating mode, target temperature and fan speed. The selected operating mode applies across the connected air-conditioning system, while temperature and fan-speed settings can be adjusted for the active zone.

  1. Active air-supply zone
  2. Cooling mode
  3. Heating mode
  4. Fan mode
  5. Dehumidification mode
  6. Target temperature
  7. Automatic, low, medium or high fan speed
  8. Equipment on/off status

PRODUCT ARCHITECTURE & MULTI-SENSOR INTEGRATION

Integrated Wired Thermostat Architecture with Onboard Multi-Sensor IAQ Monitoring

Precise HVAC control begins with stable and reliable environmental data. MAXMAC thermostats integrate a multi-sensor IAQ platform that accurately monitors temperature, humidity, CO₂, PM2.5 and TVOC conditions in individual rooms in real time.

Exploded wired thermostat showing touchscreen, enclosure, PCB and onboard sensors
1

4-Inch 480 × 480 Full-Color Capacitive Touchscreen

2

PC+ABS, UL 94 HB Flame-Retardant Housing

3

Onboard Temperature, Humidity and Optional IAQ Sensors

4

Dual RS485, Modbus-Compatible, Optional WiFi

5

Integrated Control PCB and Power Interface

Customize Your Wired Thermostat

KEY SENSOR ENGINEERING

MAXMAC IAQ multi-sensor development board for onboard wired thermostat integration

Direct PCB Onboard Integration

1

High-Precision Sensor Array

Digital temperature, humidity, CO₂, PM2.5 and TVOC sensing elements and compact modules can be integrated directly with the main control PCB. This space-efficient multi-in-one architecture combines HVAC control and room-level environmental monitoring while reducing separate wall-mounted sensors, external probe wiring and additional control panels.

Explore Multi-Sensor Modules
Wired thermostat enclosure airflow and sensor sampling cavity design

Thermal Isolation & Structural Ventilation

2

Precision Airflow Cavity

Optimized airflow paths and thermal isolation help reduce interference from internal heat generation and surrounding airflow. Purpose-designed openings guide room air naturally through the internal sensing area, helping the onboard sensors capture more representative temperature, humidity and indoor air quality data for connected HVAC control.

Multi-point wired thermostat sensor factory calibration curve

Factory Calibration & Real-Time Data Calibration

3

Multi-Point Factory Calibration

Integrated thermostat sensor modules are calibrated in high-precision temperature, humidity and gas calibration chambers before shipment to improve consistency across production batches. Built-in compensation, anti-drift algorithms and real-time calibration help maintain stable sensor output during long-term indoor operation.

THERMOSTAT PRODUCT INFORMATION

Integrated Sensor Specifications and Package Contents for Wired Thermostats

Built-in Sensor Specifications

Measurement Operating Principle Range Resolution Accuracy
PM2.5 Laser scattering 0–999 μg/m³ 1 μg/m³ ±15 μg/m³ at ≤100; ±15% above 100
CO₂ NDIR infrared 400–9999 ppm 1 ppm ±(50 ppm + 5% of reading)
Temperature CMOSens® −20°C to 85°C 1°C ±2°C
Humidity CMOSens® 1–99% RH 1% RH ±5% RH
TVOC Semiconductor conductivity 1–30,000 ppb 1 ppb —

Package Contents

Item Description Quantity
1 Pearl-cotton protective separator 1
2 Installation manual, certificate and warranty card 1
3 Integrated IAQ thermostat controller 1
4 Pearl-cotton inner tray 1
5 M4 × 30 mm mounting screws 2
6 4-pin wiring terminal 1
7 2-pin wiring terminal 1
8 Outer carton 1
9 Outer-carton label 1
Exploded view of MAXMAC wired thermostat package contents

WIRED THERMOSTAT WIRING & INSTALLATION GUIDE

Thermostat Wire Diagram & Wiring Compatibility Guide

MAXMAC wired thermostat power and RS485 system wiring reference
WIRING REFERENCE

Power and RS485 Bus Connections

Use the terminal definitions and bus topology shown to connect the wired thermostat, HVAC equipment, sensors and compatible smart-home systems. Each device on the same RS485 network should use a unique bus address.

If you need compatibility with C wire thermostats, 2-wire thermostat systems or 4-wire thermostat systems, contact our engineering team for technical evaluation and customized solutions.

Discuss Your Thermostat Project
1 Separating the wired thermostat front frame from the rear assembly
STEP A

Separate the Front and Rear Assemblies

Insert a flat-head screwdriver into the lower separation slot. Support the front frame to protect the LCD and prevent it from falling, then gently pry and slowly lift the front frame away from the rear assembly.

2 Wired thermostat power and RS485 terminal definitions
STEP B

Complete Power and RS485 Wiring

Connect power, RS485 and required control cables to the specified terminals. Confirm polarity and follow the project-specific wired thermostat instructions because valves, actuators, manifold controllers and HVAC integrations may use different wiring.

3 Mounting the wired thermostat rear assembly with the sensor port facing down
STEP C

Mount the Rear Assembly in the Wall Box

Fit the rear assembly into an 86-type wall box with the sensor sampling port facing downward. Secure it to a flat wall so the sensor can measure representative room conditions.

4 Snapping the wired thermostat front frame onto the rear assembly
STEP D

Snap the Front Assembly into Place and Commission

Secure the front frame and restore power. Set the RS485 device address and commission the connected systems. The installation manual must match the selected model, terminal definitions and final project configuration.

Installation Requirements

  1. This product must be installed by a qualified professional. Improper installation may damage the equipment.
  2. Verify that the control panel supply voltage and power rating meet the operating requirements.
  3. Install the control panel approximately 1.5 meters above the floor in a well-ventilated location.

Do Not Install in the Following Locations

  • Poorly ventilated locations, including corners and behind doors.
  • Near heating or cooling pipes, direct sunlight or other heat sources.
  • Locations with unusually low or high indoor temperatures, including walls in direct contact with the outdoors.
Diagram showing unsuitable wired thermostat locations behind a door and in an unventilated corner

INTUITIVE MULTI-SYSTEM CONTROL

Wired Thermostat Control: Precision HVAC Multi-System Integration

The main interface brings together air quality monitoring, fresh-air ventilation, fragrance, air conditioning and underfloor heating. Swipe left or right to move between function pages and operate the connected equipment. Available screens may vary according to the devices connected and the requirements of each project.

Wired thermostat air quality monitoring interface showing carbon dioxide, PM2.5, temperature and humidity
Air Quality
Wired thermostat fresh-air ventilation control interface
Fresh Air Ventilation
Wired thermostat fragrance system control interface
Fragrance System
Wired thermostat air-conditioning control interface
Air Conditioning
Wired thermostat underfloor heating control interface
Underfloor Heating

Select the settings icon in the lower-left corner of the home screen to open the settings page.

Select the power icon in the lower-right corner to switch the corresponding equipment on or off. A highlighted icon indicates that the equipment is on; a dimmed icon indicates that it is off.

Open the main settings screen and select the corresponding icon to access each settings page. Use Time Settings to set the system clock, Backlight Settings to adjust LCD brightness and screen-on duration, and About to view the software version. Select More to open Engineering Configuration. This function is intended exclusively for commissioning by qualified professionals.

Wired thermostat main settings interface with time, backlight, more and about options
Wired thermostat system time settings interface
Wired thermostat LCD brightness and screen-on duration settings interface

Underfloor Heating Control

The underfloor heating home screen displays the current room temperature and target temperature. Select the icon outside the temperature ring to adjust the operating settings. If the i fault icon appears, communication with the underfloor heating equipment is abnormal.

Underfloor heating home screen showing room temperature and target temperature
Underfloor heating target temperature adjustment interface

Set the Underfloor Heating Target Temperature

Fresh Air Ventilation Control

The fresh-air home screen displays the current indoor CO₂ and PM2.5 readings. Select the icons outside the ring to adjust the operating settings. If the i fault icon appears, communication with the connected fresh-air equipment is abnormal.

Fresh-air ventilation home screen showing carbon dioxide and PM2.5 readings
Ventilation operating mode icon Fresh-air ventilation operating mode selection interface
  • Smart Auto: Automatically adjusts airflow according to indoor air quality.
  • Standard Ventilation: Exchanges indoor and outdoor air directly without heat recovery.
  • Energy-Saving Fresh Air: Uses heat recovery to balance ventilation and energy efficiency.
  • Recirculation Purification: Filters recirculated indoor air without introducing outdoor air.
Fresh-air fan speed icon Fresh-air ventilation fan speed adjustment interface
  • Drag the slider to set the fan speed. In Smart Auto mode, the fan speed changes automatically.
Fresh-air zone control icon Fresh-air ventilation zone control interface
  • Zone control becomes available after the motorized air valves for each supply-air zone have been configured.
  • During installation, each air valve must use a unique RS485 address.

Fresh Air Ventilation Control — Zone Control

Zone control distributes airflow by adjusting the opening of the motorized air valve in each zone together with the total airflow supplied by the fresh-air unit. The system provides three operating modes. Both Smart and Manual modes allow unused zone valves to be switched off.

Smart Mode: Uses air-quality data and an intelligent algorithm to adjust the opening of each connected zone valve automatically.

Standard Mode: Opens each valve to the position defined during project commissioning; valve opening cannot be adjusted from this screen.

Manual Mode: Allows the user to adjust the opening of each zone valve independently.

Valve opening is adjustable from 0% to 100% (0% fully closed and 100% fully open) in 5% increments.

Smart mode fresh-air zone control interface
Standard mode fresh-air zone control interface
Manual mode fresh-air zone control interface

Air Conditioning Control

The air-conditioning home screen displays the current temperature and target temperature for the selected zone. Select the icons outside the temperature ring to adjust the operating settings. If the i fault icon appears, communication with the connected air-conditioning equipment is abnormal.

Air-conditioning home screen showing current and target zone temperature
Air-conditioning zone selection icon Air-conditioning zone selection interface

Switch the active air-supply zone to adjust the temperature and fan speed for that zone.

Air-conditioning operating mode icon Air-conditioning operating mode selection interface

Set the air-conditioning operating mode. This is a system-wide setting and applies to every zone.

Air-conditioning fan speed icon Air-conditioning fan speed selection interface

Set the air-conditioning fan speed for the selected zone.

Air-conditioning target temperature icon Air-conditioning target temperature adjustment interface

Set the target operating temperature for the selected zone.

Fragrance Control

The fragrance home screen displays the active fragrance and remaining cartridge level. Select the icons outside the fragrance ring to configure fragrance type, intensity and operating schedule. If the i fault icon appears, communication is abnormal or the fragrance cartridge has not been recognized. Replace the cartridge when the remaining level reaches 0%.

Fragrance control home screen showing active fragrance and remaining cartridge level
Fragrance type selection icon Fragrance type selection interface

Switch the active fragrance. The highlighted fragrance is active; this option applies to connected dual-channel fragrance generators.

Fragrance intensity icon Fragrance intensity selection interface

Set the fragrance intensity. Compatible single-channel equipment supports low and high output levels.

Fragrance schedule icon Fragrance timing and intermittent operation settings interface

Schedule the start time, set the operating duration for automatic shutdown, and configure the fragrance release and pause cycle for intermittent operation.

Explore Our Whole-Home Smart Fragrance Products

Programmable Thermostat with Lock Code for Engineering Configuration

Engineering Configuration is used to set device parameters and commission the controller’s RS485 network. This wired thermostat with lock code protection restricts access to qualified commissioning engineers. Available settings include master and secondary controller configuration, device address assignment, zone binding and motorized air-valve zero-position calibration.

Open Engineering Configuration to access detailed parameter settings. After zone air-valve configuration has been enabled, the master controller can display the opening of each motorized valve and the zone-binding list for supply-air and return-air distribution boxes. If no zone name appears in the list, the valve is not assigned to a zone and does not participate in airflow distribution.

Engineering configuration main interface
Supply-air motorized valve opening configuration interface
Return-air motorized valve opening configuration interface

If the complete list is not visible, swipe up or down to view the remaining items.

Master/Slave Setup

Select Master/Secondary Setup from Engineering Configuration to define the controller role and assign its network address.

Master Set this controller as the master control panel and enter the number n of secondary control panels connected to it. The master then recognizes secondary-panel addresses from 48 through 47+n.

Slave Set this controller as a secondary control panel and assign its address within the range 48 through 47+n. The corresponding panels are identified as Secondary Panel 1 through Secondary Panel n.

Engineering configuration menu interface
Master controller setup interface
Secondary controller setup interface

Recommended configuration order: Master/Secondary Setup → Local Controlled Devices → Zone Configuration (Zone Configuration → Supply-Air Motorized Distribution Box → Supply-Air Motorized Valve Setup).

Local Control Devices

Local Controlled Devices defines which fresh-air ventilation, air-conditioning, underfloor heating and fragrance equipment can be controlled from this panel. The selected configuration determines whether the corresponding function pages appear on the home interface.

Local controlled devices engineering configuration interface

Zone Smart Control Set Up

Zone Configuration is used to enable or disable individual zones, assign zone names and associate each zone with its controller panel.

After a motorized air distribution box is enabled, its connected air valves can be assigned to the corresponding terminal zones or left unassigned. The opening percentage of each valve can also be configured under standard operating conditions. The setup procedure is the same for supply-air and return-air motorized distribution boxes and their corresponding valves.

Zone smart control configuration interface for supply-air and return-air motorized distribution boxes

Air Distribution Box & Motorized Air Valve Configuration

When an air valve is set to Enabled, bind the terminal zone name for the duct connected to that valve. When it is set to Disabled, neither a zone name nor a valve-opening percentage can be assigned.

The zone-binding list for each air valve displays only the zone names that have been enabled in Zone Configuration.

— indicates that the terminal connected to an enabled valve has not been bound to a zone. The valve configuration becomes valid and its opening can be adjusted only after the zone is assigned.

Zone 9: — indicates that the connected terminal zone is enabled but has not been given a zone name. Correct the zone name and binding before commissioning.

After configuring the motorized valve opening, select New Air Valve Test to open the test screen, start the fresh-air system and verify the valve’s operation. Save the configuration for the new opening values to take effect.

Supply-air motorized distribution box valve enablement and zone configuration interface
Supply-air motorized valve zone-binding interface
Supply-air motorized valve opening-percentage configuration interface
New air valve test interface with fresh-air speed selection

WHY CHOOSE US

Why Choose MAXMAC: Pioneer in Integrated Sensor Thermostat Manufacturing

Backed by in-house engineering, testing and manufacturing capabilities, MAXMAC goes beyond the limits of conventional HVAC controllers. Integrating multi-in-one air quality sensing—including PM2.5, CO₂, TVOC, temperature and humidity—directly into a thermostat control board is not a simple matter of combining modules. It requires deep technical expertise and proven manufacturing capability. These two core advantages make MAXMAC a preferred smart thermostat partner for global OEM and ODM customers.

01

Deep Gas & IAQ Sensing Expertise

We do not simply purchase sensor assemblies and combine them with a controller. Years of in-house gas-sensor development have given MAXMAC a strong Sensor DNA. From optical NDIR algorithms and MOS semiconductor processes to complex temperature and humidity compensation, our engineers understand sensing technology at its foundation. This expertise allows us to integrate sensor circuitry closely with the thermostat main control board, address signal interference and thermal drift, and create an elegant modern thermostat that delivers accurate, stable air quality measurements over the long term.

02

In-House SMT & Rapid PCB Prototyping

Our in-house SMT production lines and engineering R&D team support the complete process from PCB design and interface customization to structural development. For individualized B2B OEM and ODM requirements, we provide rapid prototyping and efficient sample iteration. A fully controlled manufacturing chain gives us the flexibility to support both small pilot runs and high-volume delivery while offering cost-effective WiFi thermostat solutions that help customers significantly shorten time to market.

03

Flexible Thermostat Production with Full MES Traceability

MAXMAC combines automated production lines with manual assembly lines, allowing us to switch production methods flexibly according to thermostat structure, order volume and customer-specific requirements. This approach provides an efficient solution for thermostat manufacturing. Automated equipment safeguards consistency and delivery efficiency in volume production, while manual workstations support complex assembly, small-batch pilot runs and customized thermostat manufacturing.

At the same time, every production stage is connected to our MES system, enabling full MES traceability across material batches, PCB assembly, firmware programming, sensor calibration and finished thermostat inspection. This complete data trail gives customers more dependable quality-management assurance and supports reliable OEM/ODM thermostat volume delivery.

TESTING & VALIDATION

CNAS-Accredited Laboratory

MAXMAC’s CNAS-accredited laboratory brings product verification closer to our engineering and manufacturing teams, significantly shortening validation cycles and accelerating the transition from design to volume production. By identifying design weaknesses, potential failure modes, and risk-control points at an early stage, our laboratory capabilities help prevent issues before they reach customers or enter mass production.

Comprehensive mechanical, electrical, environmental, gas, and microbiological testing enables us to verify product performance under demanding operating conditions. This evidence-based validation process strengthens product stability, long-term reliability, and quality consistency while giving OEM/ODM customers greater confidence throughout development and delivery.

CNAS accreditation logo

Specialized Laboratory Facilities

  • Mechanical Reliability Testing Laboratory
  • Electrical Performance Testing Laboratory
  • Bacterial Culture Laboratory
  • Microbiological Testing Laboratory
  • Gas Testing Laboratory
  • Microbiological Inspection Laboratory
  • Balance Room
  • Precision Instrument Room
  • Ventilation Ducts Room
  • High Temperature Testing Laboratory
  • Product Aging Testing Laboratory
  • Impact Testing Laboratory
  • Salt Spray Testing Laboratory
  • Cold Chamber Laboratory
  • Vibration Testing Laboratory
Explore Our CNAS Laboratory
QUALIFICATION CERTIFICATES

Certifications and Quality Management

As a professional manufacturer of thermostats and HVAC controllers, our products come with a wide range of certifications and test reports to ensure quality, safety, and performance. These include ISO 14001, ISO 45001, ISO 9001, IATF 16949, CNAS laboratory accreditation, and more. These certifications reflect our commitment to delivering reliable thermostat and HVAC control solutions that meet global standards.

ISO 14001 Certificate
ISO 14001 Certificate
ISO 45001 Certificate
ISO 45001 Certificate
ISO 9001 Certificate
ISO 9001 Certificate
IATF 16949 Certificate
IATF 16949 Certificate
CNAS Laboratory Accreditation
CNAS Laboratory Accreditation
CNAS Laboratory Accreditation Certificate
CNAS Laboratory Accreditation Certificate

TRUSTED PARTNERS

Trusted Customers

MAXMAC supports established HVAC, thermal-management and building-technology companies with integrated sensing, thermostat controller development and OEM/ODM manufacturing services.

From product definition and PCB engineering to validation and volume delivery, our teams work closely with customers to bring reliable, connected climate-control products to market.

HVAC Brands Thermal Management OEM/ODM Partners
Carrier logo Valeo logo DENSO logo Hisense logo Honeywell logo HITACHI logo Panasonic logo YENOVA logo Habit@ logo MAHLE logo
FAQS

Frequently Asked Questions About Wired Thermostats

How to wire a thermostat?

Confirm power, control terminals, communication lines and equipment wiring before installation. For wired RS485 projects, also confirm the bus address and polarity. Always follow the terminal definitions and wiring diagram supplied for the selected thermostat model and connected HVAC equipment.

Do hard wired thermostats need batteries?

Most hard wired thermostats use wired power instead of batteries, but the final power method depends on the selected model and project design.

How does an air conditioner thermostat work?

It measures room conditions, compares them with the target setting and sends control commands to the air-conditioning or HVAC system according to the configured logic.

What is the difference between 5 wire, 6 wire and 7 wire thermostats?

The difference usually reflects available control signals, power wiring and HVAC function support. Compatibility should be judged by the equipment terminal definition, not only by the number of wires.

Is an isolation relay for thermostat control built in?

MAXMAC wired thermostat solutions can include an internally integrated isolation relay according to the selected hardware configuration and connected equipment requirements. This can simplify external wiring while helping isolate the thermostat control circuit from the connected HVAC load. Final relay specifications and compatibility are confirmed during project evaluation.

What is the Minimum Order Quantity (MOQ) for B2B wired thermostat procurement?

Our standard Minimum Order Quantity for B2B wired thermostat procurement and volume orders is 1,000 units. Final MOQ, pricing and production lead time are confirmed according to the selected model, communication protocol, sensor configuration, customization scope and order quantity.

Can we order wired thermostat samples before bulk production?

Yes. Sample units can be supplied for engineering evaluation, wiring compatibility testing, communication testing and project approval before volume production. Sample availability, configuration, cost and preparation time depend on the selected model and customization requirements.

Does MAXMAC support OEM/ODM customization for bulk wired thermostat orders?

Yes. MAXMAC provides OEM/ODM customization for B2B bulk orders and private-label projects. Available options include enclosure colors, logo printing, user-interface design, sensor configurations, RS485 and Modbus communication, optional WiFi, software control logic, packaging and labeling. Our engineering team can evaluate project requirements and develop a customized wired thermostat platform for volume production.

Provide Your Details for Professional Product Consultation

Our product experts will provide the most suitable air solutions and product recommendations.