MAXMAC smart thermostat with integrated indoor air quality monitoring in a bedroom

Thermostat & HVAC Control Manufacturer

Custom Smart Thermostats with Integrated Multi-in-One IAQ Sensor Boards & OEM/ODM HVAC Controller Solutions

As the world's first China-based manufacturer to integrate multi-in-one air quality sensors—including PM2.5, CO₂, TVOC, temperature and humidity sensing—directly into a thermostat control board, MAXMAC provides HVAC equipment manufacturers and brands with pioneering intelligent thermostat platforms, industrial and residential HVAC thermostat products, and complete OEM/ODM solutions.

A single control board delivers both precise environmental temperature control and real-time indoor air quality (IAQ) monitoring. For partners developing remote thermostat products or custom smart thermostat solutions for specific markets, we provide a complete, configurable temperature-control platform with optional color or segment displays. Communication options can be tailored to include WiFi, Modbus RS485, Ethernet, Zigbee, BACnet and Matter. Our factory is certified to ISO 9001 and IATF 16949 and accredited by CNAS, while our products comply with CE, FCC and RoHS requirements. From custom hardware to internationally recognized compliance, we help your products stand out in the market.

PRODUCT CATALOG

Explore Our Complete Types of Thermostats for Global B2B Markets

Compare configurable thermostat platforms for heating, cooling, ventilation and building-control applications, each designed to present temperature and integrated IAQ sensor data through a clear color or segment display.

HEATING

Boiler Thermostat

MAXMAC digital thermostat solutions connect with wall-hung boilers and conventional boiler systems through customizable wired or wireless interfaces. Integrated PM2.5, CO₂, TVOC, temperature and humidity data is presented clearly on an optional color or segment display. Flexible time programming and precise temperature adjustment work with the built-in MAXMAC multi-sensor platform to match heating operation to actual room conditions and support a more comfortable indoor environment.

Check details
WIRELESS

Wireless Thermostat

Developed for projects where control wiring is impractical, this wireless programmable thermostat platform supports customized WiFi and Zigbee communication. Users can program time and temperature while retaining the MAXMAC fragrance-system control unit for scheduling fragrance release, switching scents and adjusting intensity. The built-in MAXMAC multi-sensor platform monitors PM2.5, CO₂, TVOC, temperature and humidity, providing strong room-level IAQ inputs for HVAC decisions based on actual room conditions. Choose a color or segment display.

Check details
WIFI CONNECTED

WiFi Thermostats

Each MAXMAC WiFi thermostat is designed for modern smart homes and commercial buildings, with remote app control and cloud connectivity. The built-in MAXMAC multi-sensor platform monitors PM, CO₂, TVOC, temperature and humidity, giving connected HVAC equipment live IAQ data for more responsive room control.

Check details
WIRED BMS

Wired Thermostat

Designed for smart commercial buildings and engineering projects, this wired thermostat supports standard industrial buses including Modbus RS485, Ethernet and BACnet. We provide a clear thermostat wiring diagram and standardized terminal definitions for efficient on-site installation. The built-in MAXMAC multi-sensor platform combines environmental monitoring with precise temperature control, supplying room-level IAQ data that a BMS can use to coordinate HVAC operation around actual building conditions. Color and segment displays are available.

Check details
PROGRAMMABLE

Programmable Thermostats

Our programmable thermostats provide flexible time and temperature scheduling plus six customizable operating scenes that better match daily routines. They can also integrate the MAXMAC smart fragrance-system control unit for programmable whole-home scent management. The built-in MAXMAC multi-sensor platform monitors PM, CO₂, TVOC, temperature and humidity, supplying comprehensive room-level IAQ data while schedules and operating scenes align HVAC operation with occupied periods and user routines. Color and segment displays are available.

Check details
UNDERFLOOR

Underfloor Heating Thermostat

The product family includes electric underfloor heating thermostats and hydronic underfloor heating thermostats, with optional color touchscreens or high-contrast segment displays and WiFi or RS485 connectivity. For water-based heating systems, the controller can be configured around the equipment, valve and control requirements of each project. The built-in MAXMAC multi-sensor platform unifies floor-heating control with whole-home indoor air quality monitoring.

Check details
FCU / VRF

FCU Thermostat

This AC thermostat is designed for fan coil units, central air conditioning and VRF systems, with three-speed fan and two-pipe or four-pipe valve control. Modbus RS485, Zigbee and Ethernet communication simplify integration with a building management system. The built-in MAXMAC multi-sensor platform monitors PM2.5, CO₂, TVOC, temperature and humidity, enabling coordinated control of fan speed, valve operation and indoor air quality.

Check details
HEAT PUMP

Heat Pump Thermostat

This multifunctional HVAC thermostat supports air-source and ground-source heat pump systems. Dual RS485 buses can be extended with WiFi, Zigbee or Modbus connectivity, and customers can select a high-resolution color display or a low-power segment display. The built-in MAXMAC multi-sensor platform monitors PM2.5, CO₂, TVOC, temperature and humidity, giving automatic HVAC logic real-time room data for more responsive heating and cooling control.

Check details
VENTILATION

Ventilation Controller

Engineered for fresh-air systems, energy recovery and heat recovery ventilators, and combined fresh-air dehumidification equipment, this intelligent thermostat functions as a pioneering smart thermostat hardware platform. Its onboard MAXMAC multi-sensor platform continuously detects PM2.5, CO₂, TVOC and humidity, automatically adjusting fan speed and opening fresh-air dampers to deliver genuinely intelligent indoor air quality management.

Check details

OEM/ODM SMART THERMOSTAT PLATFORM

Custom Smart Thermostat Platform for OEM & ODM HVAC Products

Develop an HVAC thermostat around your equipment, market and brand requirements. MAXMAC brings the touchscreen, control board, sensor inputs, communication interfaces and firmware together in one customizable platform—from smart thermostats for home HVAC systems to commercial equipment and industrial climate control.

The platform can be configured as a programmable thermostat, digital thermostat or WiFi thermostat, with dual RS485, Modbus-compatible communication and optional WiFi selected according to project requirements. Built-in sensing can combine PM2.5, CO₂, temperature and humidity, with expandable TVOC capability, helping your team shorten integration work and move from product definition to validated production.

  • Custom touchscreen UI, language and brand identity
  • Dual RS485, Modbus-compatible and optional WiFi connectivity
  • Integrated PM2.5, CO₂, temperature and humidity sensing
  • Custom housing, mounting structure, logo and packaging
  • Firmware, HVAC control logic and PCB adaptation
Discuss Your OEM/ODM Thermostat
Front and rear views of a custom MAXMAC smart HVAC thermostat controller
Onecoordinated HVAC interface
Flexiblecommunication options
OEM/ODMengineering support

PRODUCT SERIES

Explore Our Thermostat & HVAC Controller Series

Compare five product families, then select a model to explore its specifications, sensing capabilities and control options.

PRODUCT ARCHITECTURE

Integrated Hardware Engineered for Smarter HVAC Control

Exploded view of the MAXMAC smart thermostat display housing sensor boards and rear enclosure
1

4-Inch 480 × 480 dpi Full-Color Capacitive LCD Touchscreen

5

M4 Screw Fastening

2

PC+ABS, UL 94 HB Flame-Retardant Housing

3

MAXMAC IAQ Multi-Sensor (PM + CO₂ + Temperature & Humidity + Expandable TVOC)

4

Dual RS485, Modbus-Compatible, Optional WiFi

Customize Your Thermostat

1 Customized logo and package

2 Customized software (change to customer’s user interface and control logic)

3 Customized hardware (Change the PCB and schematic based on the request)

THERMOSTAT WIRING DIAGRAM

Clear Thermostat Wiring Diagram for Reliable RS485 HVAC System Integration

MAXMAC thermostat power and RS485 system wiring reference
WIRING REFERENCE

Power and RS485 Bus Connections

Use the terminal definitions and bus topology shown to connect the controller, HVAC equipment, sensors and compatible smart-home systems. Each device on the same RS485 network must use a unique bus address.

Discuss Your Thermostat Project

Installation Requirements

  1. This product must be installed by a qualified professional. Improper installation may damage the equipment.
  2. Verify that the control panel supply voltage and power rating meet the operating requirements.
  3. Install the control panel approximately 1.5 meters above the floor in a well-ventilated location.

Do Not Install in the Following Locations

  • Poorly ventilated locations, including corners and behind doors.
  • Near heating or cooling pipes, direct sunlight or other heat sources.
  • Locations with unusually low or high indoor temperatures, including walls in direct contact with the outdoors.
Diagram showing unsuitable thermostat installation locations behind a door and in an unventilated corner

THERMOSTAT PRODUCT INFORMATION

Integrated Sensor Specifications and Package Contents for Smart Thermostats

Built-in Sensor Specifications

Measurement Operating Principle Range Resolution Accuracy
PM2.5Laser scattering0–999 μg/m³1 μg/m³±15 μg/m³ at ≤100; ±15% above 100
CO₂NDIR infrared400–9999 ppm1 ppm±(50 ppm + 5% of reading)
TemperatureCMOSens®−20°C to 85°C1°C±2°C
HumidityCMOSens®1–99% RH1% RH±5% RH
TVOCSemiconductor conductivity1–30,000 ppb1 ppb—

Package Contents

ItemDescriptionQuantity
1Pearl-cotton protective separator1
2Installation manual, certificate and warranty card1
3Integrated IAQ thermostat controller1
4Pearl-cotton inner tray1
5M4 × 30 mm mounting screws2
64-pin wiring terminal1
72-pin wiring terminal1
8Outer carton1
9Outer-carton label1
Exploded view of MAXMAC thermostat package contents

THERMOSTAT INSTALLATION GUIDE

Step-by-Step Thermostat Installation Guide for Secure and Reliable HVAC Controller Setup

1Separating the thermostat front frame from the rear cover assembly
STEP A

Separate the Front and Rear Assemblies

Insert a flat-head screwdriver into the separation slot on the bottom or lower side. Support the front frame with one hand to protect the LCD and prevent it from falling, then gently pry and slowly lift the front frame to separate the front and rear assemblies.

2Thermostat power and communication terminal wiring definitions
STEP B

Complete Power and Communication Wiring

Following the controller wiring definitions, connect the power cable and communication lines to the specified terminals in sequence.

3Mounting the thermostat rear assembly in a wall box with the sensor sampling port facing down
STEP C

Mount the Rear Assembly in the Wall Box

Place the controller rear assembly in an 86-type wall box with the sensor sampling port facing downward. Ensure the wall surface is flat, then secure the assembly with screws.

4Snapping the thermostat front frame securely onto the rear assembly
STEP D

Snap the Front Assembly into Place and Commission

Snap the front frame securely onto the rear assembly and switch on the power. After the LCD illuminates, proceed with commissioning of the controlled equipment.

INTUITIVE MULTI-SYSTEM CONTROL

Thermostat Control: Precision HVAC Multi-System Integration

The main interface brings together air quality monitoring, fresh-air ventilation, fragrance, air conditioning and underfloor heating. Swipe left or right to move between function pages and operate the connected equipment. Available screens may vary according to the devices connected and the requirements of each project.

Thermostat air quality monitoring interface showing carbon dioxide, PM2.5, temperature and humidity
Air Quality
Thermostat fresh-air ventilation control interface
Fresh Air Ventilation
Thermostat fragrance system control interface
Fragrance System
Thermostat air-conditioning control interface
Air Conditioning
Thermostat underfloor heating control interface
Underfloor Heating

Select the settings icon in the lower-left corner of the home screen to open the settings page.

Select the power icon in the lower-right corner to switch the corresponding equipment on or off. A highlighted icon indicates that the equipment is on; a dimmed icon indicates that it is off.

Open the main settings screen and select the corresponding icon to access each settings page. Use Time Settings to set the system clock, Backlight Settings to adjust LCD brightness and screen-on duration, and About to view the software version. Select More to open Engineering Configuration. This function is intended exclusively for commissioning by qualified professionals.

Thermostat main settings interface with time, backlight, more and about options
Thermostat system time settings interface
Thermostat LCD brightness and screen-on duration settings interface

Underfloor Heating Control

The underfloor heating home screen displays the current room temperature and target temperature. Select the icon outside the temperature ring to adjust the operating settings. If the i fault icon appears, communication with the underfloor heating equipment is abnormal.

Underfloor heating home screen showing room temperature and target temperature
Underfloor heating target temperature adjustment interface

Set the Underfloor Heating Target Temperature

Fresh Air Ventilation Control

The fresh-air home screen displays the current indoor CO₂ and PM2.5 readings. Select the icons outside the ring to adjust the operating settings. If the i fault icon appears, communication with the connected fresh-air equipment is abnormal.

Fresh-air ventilation home screen showing carbon dioxide and PM2.5 readings
Ventilation operating mode icon Fresh-air ventilation operating mode selection interface
  • Smart Auto: Automatically adjusts airflow according to indoor air quality.
  • Standard Ventilation: Exchanges indoor and outdoor air directly without heat recovery.
  • Energy-Saving Fresh Air: Uses heat recovery to balance ventilation and energy efficiency.
  • Recirculation Purification: Filters recirculated indoor air without introducing outdoor air.
Fresh-air fan speed icon Fresh-air ventilation fan speed adjustment interface
  • Drag the slider to set the fan speed. In Smart Auto mode, the fan speed changes automatically.
Fresh-air zone control icon Fresh-air ventilation zone control interface
  • Zone control becomes available after the motorized air valves for each supply-air zone have been configured.
  • During installation, each air valve must use a unique RS485 address.

Fresh Air Ventilation Control — Zone Control

Zone control distributes airflow by adjusting the opening of the motorized air valve in each zone together with the total airflow supplied by the fresh-air unit. The system provides three operating modes. Both Smart and Manual modes allow unused zone valves to be switched off.

Smart Mode: Uses air-quality data and an intelligent algorithm to adjust the opening of each connected zone valve automatically.

Standard Mode: Opens each valve to the position defined during project commissioning; valve opening cannot be adjusted from this screen.

Manual Mode: Allows the user to adjust the opening of each zone valve independently.

Valve opening is adjustable from 0% to 100% (0% fully closed and 100% fully open) in 5% increments.

Smart mode fresh-air zone control interface
Standard mode fresh-air zone control interface
Manual mode fresh-air zone control interface

Air Conditioning Control

The air-conditioning home screen displays the current temperature and target temperature for the selected zone. Select the icons outside the temperature ring to adjust the operating settings. If the i fault icon appears, communication with the connected air-conditioning equipment is abnormal.

Air-conditioning home screen showing current and target zone temperature
Air-conditioning zone selection icon Air-conditioning zone selection interface

Switch the active air-supply zone to adjust the temperature and fan speed for that zone.

Air-conditioning operating mode icon Air-conditioning operating mode selection interface

Set the air-conditioning operating mode. This is a system-wide setting and applies to every zone.

Air-conditioning fan speed icon Air-conditioning fan speed selection interface

Set the air-conditioning fan speed for the selected zone.

Air-conditioning target temperature icon Air-conditioning target temperature adjustment interface

Set the target operating temperature for the selected zone.

Fragrance Control

The fragrance home screen displays the active fragrance and remaining cartridge level. Select the icons outside the fragrance ring to configure fragrance type, intensity and operating schedule. If the i fault icon appears, communication is abnormal or the fragrance cartridge has not been recognized. Replace the cartridge when the remaining level reaches 0%.

Fragrance control home screen showing active fragrance and remaining cartridge level
Fragrance type selection icon Fragrance type selection interface

Switch the active fragrance. The highlighted fragrance is active; this option applies to connected dual-channel fragrance generators.

Fragrance intensity icon Fragrance intensity selection interface

Set the fragrance intensity. Compatible single-channel equipment supports low and high output levels.

Fragrance schedule icon Fragrance timing and intermittent operation settings interface

Schedule the start time, set the operating duration for automatic shutdown, and configure the fragrance release and pause cycle for intermittent operation.

Explore Our Whole-Home Smart Fragrance Products

Engineering Configuration

Engineering Configuration is used to set device parameters and commission the controller’s RS485 network. It includes master and secondary controller panel configuration, device address assignment, zone binding and motorized air-valve zero-position calibration. This area is intended exclusively for qualified commissioning engineers and requires password verification.

Open Engineering Configuration to access detailed parameter settings. After zone air-valve configuration has been enabled, the master controller can display the opening of each motorized valve and the zone-binding list for supply-air and return-air distribution boxes. If no zone name appears in the list, the valve is not assigned to a zone and does not participate in airflow distribution.

Engineering configuration main interface
Supply-air motorized valve opening configuration interface
Return-air motorized valve opening configuration interface

If the complete list is not visible, swipe up or down to view the remaining items.

Master/Slave Setup

Select Master/Secondary Setup from Engineering Configuration to define the controller role and assign its network address.

MasterSet this controller as the master control panel and enter the number n of secondary control panels connected to it. The master then recognizes secondary-panel addresses from 48 through 47+n.

SlaveSet this controller as a secondary control panel and assign its address within the range 48 through 47+n. The corresponding panels are identified as Secondary Panel 1 through Secondary Panel n.

Engineering configuration menu interface
Master controller setup interface
Secondary controller setup interface

Recommended configuration order: Master/Secondary Setup → Local Controlled Devices → Zone Configuration (Zone Configuration → Supply-Air Motorized Distribution Box → Supply-Air Motorized Valve Setup).

Local Control Devices

Local Controlled Devices defines which fresh-air ventilation, air-conditioning, underfloor heating and fragrance equipment can be controlled from this panel. The selected configuration determines whether the corresponding function pages appear on the home interface.

Local controlled devices engineering configuration interface

Zone Smart Control Set Up

Zone Configuration is used to enable or disable individual zones, assign zone names and associate each zone with its controller panel.

After a motorized air distribution box is enabled, its connected air valves can be assigned to the corresponding terminal zones or left unassigned. The opening percentage of each valve can also be configured under standard operating conditions. The setup procedure is the same for supply-air and return-air motorized distribution boxes and their corresponding valves.

Zone smart control configuration interface for supply-air and return-air motorized distribution boxes

Zone Configuration

The Zone Configuration interface uses Enabled and Disabled to control each zone, assign its name and bind it to the appropriate controller panel. When the same zone name is used for multiple areas, add a numeric suffix x so each area is identified as Name_x, for example, Aisle_1.

Zone binding can be configured only from the Master controller. By default, the master controller is bound to Zone 1, with the zone set to Enabled. Installing the master controller in a shared area is recommended for easier system management. The controller-panel list is generated dynamically according to the number of secondary controllers defined in the master/secondary configuration.

— indicates that an enabled zone has not yet been given a zone name or assigned to a secondary controller. Every enabled zone must be named; a zone without its own controller panel can remain unbound.

Zone enablement, naming and controller-panel binding interface
Zone name selection and numeric suffix configuration interface
Zone controller-panel binding selection interface

Air Distribution Box & Motorized Air Valve Configuration

When an air valve is set to Enabled, bind the terminal zone name for the duct connected to that valve. When it is set to Disabled, neither a zone name nor a valve-opening percentage can be assigned.

The zone-binding list for each air valve displays only the zone names that have been enabled in Zone Configuration.

— indicates that the terminal connected to an enabled valve has not been bound to a zone. The valve configuration becomes valid and its opening can be adjusted only after the zone is assigned.

Zone 9: — indicates that the connected terminal zone is enabled but has not been given a zone name. Correct the zone name and binding before commissioning.

After configuring the motorized valve opening, select New Air Valve Test to open the test screen, start the fresh-air system and verify the valve’s operation. Save the configuration for the new opening values to take effect.

Supply-air motorized distribution box valve enablement and zone configuration interface
Supply-air motorized valve zone-binding interface
Supply-air motorized valve opening-percentage configuration interface
New air valve test interface with fresh-air speed selection

WHY CHOOSE US

Why Choose MAXMAC: Pioneer in Integrated Sensor Thermostat Manufacturing

Backed by in-house engineering, testing and manufacturing capabilities, MAXMAC goes beyond the limits of conventional HVAC controllers. Integrating multi-in-one air quality sensing—including PM2.5, CO₂, TVOC, temperature and humidity—directly into a thermostat control board is not a simple matter of combining modules. It requires deep technical expertise and proven manufacturing capability. These two core advantages make MAXMAC a preferred smart thermostat partner for global OEM and ODM customers.

01

Deep Gas & IAQ Sensing Expertise

We do not simply purchase sensor assemblies and combine them with a controller. Years of in-house gas-sensor development have given MAXMAC a strong Sensor DNA. From optical NDIR algorithms and MOS semiconductor processes to complex temperature and humidity compensation, our engineers understand sensing technology at its foundation. This expertise allows us to integrate sensor circuitry closely with the thermostat main control board, address signal interference and thermal drift, and create an elegant modern thermostat that delivers accurate, stable air quality measurements over the long term.

02

In-House SMT & Rapid PCB Prototyping

Our in-house SMT production lines and engineering R&D team support the complete process from PCB design and interface customization to structural development. For individualized B2B OEM and ODM requirements, we provide rapid prototyping and efficient sample iteration. A fully controlled manufacturing chain gives us the flexibility to support both small pilot runs and high-volume delivery while offering cost-effective WiFi thermostat solutions that help customers significantly shorten time to market.

03

Flexible Thermostat Production with Full MES Traceability

MAXMAC combines automated production lines with manual assembly lines, allowing us to switch production methods flexibly according to thermostat structure, order volume and customer-specific requirements. This approach provides an efficient solution for thermostat manufacturing. Automated equipment safeguards consistency and delivery efficiency in volume production, while manual workstations support complex assembly, small-batch pilot runs and customized thermostat manufacturing.

At the same time, every production stage is connected to our MES system, enabling full MES traceability across material batches, PCB assembly, firmware programming, sensor calibration and finished thermostat inspection. This complete data trail gives customers more dependable quality-management assurance and supports reliable OEM/ODM thermostat volume delivery.

TESTING & VALIDATION

CNAS-Accredited Laboratory

MAXMAC’s CNAS-accredited laboratory brings product verification closer to our engineering and manufacturing teams, significantly shortening validation cycles and accelerating the transition from design to volume production. By identifying design weaknesses, potential failure modes, and risk-control points at an early stage, our laboratory capabilities help prevent issues before they reach customers or enter mass production.

Comprehensive mechanical, electrical, environmental, gas, and microbiological testing enables us to verify product performance under demanding operating conditions. This evidence-based validation process strengthens product stability, long-term reliability, and quality consistency while giving OEM/ODM customers greater confidence throughout development and delivery.

CNAS accreditation logo

Specialized Laboratory Facilities

  • Mechanical Reliability Testing Laboratory
  • Electrical Performance Testing Laboratory
  • Bacterial Culture Laboratory
  • Microbiological Testing Laboratory
  • Gas Testing Laboratory
  • Microbiological Inspection Laboratory
  • Balance Room
  • Precision Instrument Room
  • Ventilation Ducts Room
  • High Temperature Testing Laboratory
  • Product Aging Testing Laboratory
  • Impact Testing Laboratory
  • Salt Spray Testing Laboratory
  • Cold Chamber Laboratory
  • Vibration Testing Laboratory
Explore Our CNAS Laboratory

APPLICATION SCENARIOS

Next-Gen Smart Thermostats for Home & Commercial Air Quality Management

Modern smart thermostat for residential and home HVAC systems

Custom Smart Thermostats for Residential & Home HVAC Systems

MAXMAC develops modern smart thermostat platforms for residential and home HVAC brands. When a thermostat integrates an indoor air quality monitor, it becomes more than a simple temperature controller—it becomes an intelligent safeguard for the health of the entire family. In a nursery or pet room, users can view real-time air conditions while HVAC equipment responds precisely only when IAQ readings reach defined thresholds. This demand-based coordination creates a reassuring living experience and avoids unnecessary equipment operation by responding to actual room conditions. By combining environmental sensing with precise climate control, MAXMAC helps OEM and ODM partners create differentiated smart thermostats for safer, healthier and more responsive homes.

Contact Us
Smart thermostat and IAQ management for commercial buildings offices and schools

Commercial Buildings, Offices & Schools

In offices, commercial buildings and schools, changing occupancy causes indoor air quality and HVAC loads to fluctuate throughout the day. A thermostat with integrated IAQ monitoring can track CO₂, TVOC, temperature and humidity in real time, then coordinate HVAC and fresh-air systems according to actual occupancy demand. Ventilation and air conditioning can respond when air-quality readings or loads cross defined thresholds instead of operating continuously at full output. This demand-responsive control helps limit unnecessary equipment runtime while maintaining a fresh, healthy environment for work and learning. MAXMAC integrated thermostats support Modbus RS485, Ethernet and BACnet connectivity for BMS integration, making them a practical solution for responsive commercial HVAC operation and high indoor-health standards.

Contact Us
Industrial thermostat for cleanroom hospitality and precision climate control

Cleanroom, Hospitality & Industrial Climate Control

In cleanrooms, premium hotels and industrial climate-control environments, precise temperature, humidity and particulate control—including PM2.5 and PM10—directly affects production compliance, quality standards and guest experience. A thermostat with integrated IAQ monitoring continuously senses microenvironment conditions and precisely triggers connected compensation and filtration equipment. This dynamic “measure precisely, respond on demand” control logic maintains around-the-clock environmental stability while avoiding unnecessary operation of high-power industrial HVAC equipment. With onboard high-accuracy sensors and industrial communication buses, MAXMAC delivers a stable, responsive environmental control terminal for demanding industrial and commercial applications.

Contact Us
QUALIFICATION CERTIFICATES

Certifications and Quality Management

As a professional manufacturer of thermostats and HVAC controllers, our products come with a wide range of certifications and test reports to ensure quality, safety, and performance. These include ISO 14001, ISO 45001, ISO 9001, IATF 16949, CNAS laboratory accreditation, and more. These certifications reflect our commitment to delivering reliable thermostat and HVAC control solutions that meet global standards.

ISO 14001 Certificate
ISO 14001 Certificate
ISO 45001 Certificate
ISO 45001 Certificate
ISO 9001 Certificate
ISO 9001 Certificate
IATF 16949 Certificate
IATF 16949 Certificate
CNAS Laboratory Accreditation
CNAS Laboratory Accreditation
CNAS Laboratory Accreditation Certificate
CNAS Laboratory Accreditation Certificate

TRUSTED PARTNERS

Trusted Customers

MAXMAC supports established HVAC, thermal-management and building-technology companies with integrated sensing, thermostat controller development and OEM/ODM manufacturing services.

From product definition and PCB engineering to validation and volume delivery, our teams work closely with customers to bring reliable, connected climate-control products to market.

HVAC Brands Thermal Management OEM/ODM Partners
Carrier logo Valeo logo DENSO logo Hisense logo Honeywell logo HITACHI logo Panasonic logo YENOVA logo Habit@ logo MAHLE logo

Build a Thermostat Around Your HVAC Platform

Share your equipment type, control functions, communication needs and interface direction.

Contact an Engineer
FAQS

Frequently Asked Questions About Integrated IAQ Thermostats

What does thermostat mean in an integrated IAQ and HVAC control system?

An integrated IAQ thermostat combines traditional temperature control with multi-parameter indoor air quality sensing. It monitors temperature, humidity, PM2.5, CO₂ and TVOC, providing room-level environmental data for coordinated HVAC, ventilation and heating control.

How do thermostats work with built-in IAQ sensors?

Thermostats with built-in sensors continuously monitor temperature, humidity, PM2.5, CO₂ and TVOC. Based on preset control logic, they can trigger heating, cooling, underfloor heating or fresh-air ventilation in response to actual room conditions.

What is a smart thermostat, and how does it work with air quality sensors?

A smart thermostat combines programmable temperature control, communication connectivity and environmental sensing. It can connect with WiFi, Zigbee, RS485, Modbus or Ethernet systems, allowing users and building management platforms to monitor IAQ data and adjust HVAC settings remotely.

How does a boiler thermostat work when integrated with IAQ sensing?

A boiler thermostat monitors room temperature and sends heating demand signals to the boiler through dry contacts, wired communication or customized control interfaces. With integrated IAQ sensing, it can also use PM2.5, CO₂, TVOC, humidity and temperature data to improve heating and ventilation control logic.

How to install a thermostat and complete a home thermostat replacement?

Before installation, confirm the power supply, terminal definitions, controlled equipment and communication protocol. During a home thermostat replacement, installers should verify the existing wiring and make sure it is compatible with the new thermostat’s RS485, relay, Ethernet, WiFi or Zigbee configuration.

What should be checked when a thermostat not working issue occurs?

When a thermostat is not working, check the power supply, terminal wiring, communication settings, relay output, sensor calibration and connection to the HVAC equipment. For networked models, also verify WiFi, Zigbee, RS485, Modbus or Ethernet communication status.

Provide Your Details for Professional Product Consultation