MAXMAC touchscreen heat pump thermostat with integrated air quality sensing

Heat Pump Thermostats

Smart Heat Pump Thermostats Manufacturer & OEM Supplier with Integrated Multi-Sensor IAQ Platform

As a professional HVAC control and sensing solutions provider, MAXMAC supplies next-generation smart thermostat for heat pump applications and project-specific thermostat for heat pump solutions to B2B customers worldwide. More than a basic temperature controller, each product can integrate MAXMAC's multi-in-one air quality sensor platform for real-time monitoring of PM2.5, CO₂, TVOC, temperature and humidity.

Designed for residential, apartment, hotel and light-commercial HVAC projects, MAXMAC heat pump thermostats support heating, cooling, underfloor heating and compatible fresh-air systems through flexible wired or wireless communication. OEM/ODM customers can customize hardware, UI, control logic, sensor configuration and communication protocols according to project requirements. Production operates under strict ISO 9001 and IATF 16949 quality management systems, and our manufacturing base houses a national CNAS-accredited standard laboratory for environmental simulation, aging and consistency testing from the earliest stages of product development. All MAXMAC thermostat products fully comply with CE and RoHS.

HEAT PUMP THERMOSTAT SERIES

Explore Our Next-Gen Heat Pump Compatible Thermostat Series

6-A6312-K wired digital heat pump thermostat
6-A6312-K

6-A6312-K Wired Digital Heat Pump Thermostat

Hardware
4-inch full-color touchscreen
Connectivity
Wired · RS485 · Modbus / Ethernet expandable · No WiFi
Built-in Sensors
Temperature + Humidity

The 6-A6312-K is a wired digital heat pump thermostat built around stable RS485 bus communication. It features a 4-inch full-color touchscreen and integrated temperature and humidity sensing. Designed for heat pump and HVAC control projects, it provides reliable room-level temperature regulation while coordinating heating, cooling, ventilation and related indoor comfort systems through one wall-mounted interface.

Read more
6-A6314-K WiFi thermostat for heat pump
6-A6314-K

6-A6314-K WiFi Thermostat for Heat Pump

Hardware
4-inch full-color touchscreen · 12 V / 1 A
Connectivity
WiFi + RS485 · Zigbee expandable
Built-in Sensors
Temperature + Humidity

The 6-A6314-K combines WiFi cloud connectivity with wired RS485 bus communication, making it suitable for smart heat pump thermostat projects that require both local stability and remote access. Its 4-inch touchscreen gives users clear control over heating, cooling and comfort settings, while the platform can coordinate air conditioning, fresh-air ventilation, underfloor heating and fragrance systems from one device.

Read more
6-A6315-K programmable thermostat for heat pump
6-A6315-K

6-A6315-K Programmable Thermostat for Heat Pump

Hardware
4-inch full-color touchscreen · 12 V / 1 A
Connectivity
WiFi + RS485 · Modbus / RF / Zigbee / Ethernet expandable
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A6315-K is a programmable thermostat for heat pump systems with integrated CO₂, PM2.5, temperature and humidity sensing. It supports scheduled heating and cooling control by time period, room demand and project-defined operating modes, while real-time air quality data helps coordinate heat pump operation with fresh-air ventilation and other indoor comfort systems. It is suitable for energy-efficient residential, apartment and light-commercial HVAC projects.

Read more
6-A2302-H AC heat pump thermostat
6-A2302-H

6-A2302-H AC Heat Pump Thermostat

Hardware
6-inch full-color touchscreen · 12 V / 1 A
Connectivity
WiFi + RS485 · Modbus / RF / Zigbee / Ethernet expandable
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A2302-H is a compact AC heat pump thermostat designed for projects that need integrated air-conditioning and heat pump control in a smaller wall-mounted format. With WiFi and RS485 communication, it can support remote access, local bus control and expandable smart-home protocols. Integrated CO₂, PM2.5, temperature and humidity sensing helps the thermostat respond to both comfort demand and indoor air quality conditions.

Read more
6-A5601-K digital thermostat for heat pump
6-A5601-K

6-A5601-K Digital Thermostat for Heat Pump

Hardware
4-inch full-color touchscreen · 12 V / 1 A
Connectivity
WiFi + RS485 · Modbus / RF / Zigbee / Ethernet expandable
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A5601-K is a remote digital thermostat for heat pump applications, combining a 4-inch full-color touchscreen with WiFi and RS485 connectivity. Integrated CO₂, PM2.5, temperature and humidity sensors support real-time indoor environmental monitoring, while the controller can manage heating, cooling, fresh-air ventilation, underfloor heating and fragrance systems through a unified interface. It is well suited to high-end residential, hotel and commercial HVAC projects.

Read more

SMART HEAT PUMP CONTROL LOGIC

Smart Heat Pump Thermostat Settings for Heating, Cooling & Emergency Heat

A heat pump thermostat should make heating and cooling easier to manage, not harder. MAXMAC can customize the settings page according to the actual heat pump system, so users can adjust temperature, choose the working mode and check system status from one clear interface.

For projects that also connect air conditioning, fresh-air ventilation or backup heating, the control logic can be planned together with the wiring and equipment setup. This helps the thermostat send the right command to the right device, instead of treating every HVAC system the same way.

If one controller is used for both heat pump and air conditioning, the interface can be customized around the functions users really need on site. The goal is simple operation for users and reliable control for the project.

Heating & Emergency Heat

Thermostat Setting

Sets the target temperature and operating mode

Room Condition Detection

Compares real-time temperature with the setpoint

Heat Pump Operation

Sends the required heating command to the system

Emergency Heat Support

Activates project-defined backup heating when required

Cooling & Multi-System Coordination

Cooling Demand Detection

Identifies when the room temperature exceeds the setpoint

Cooling Mode Control

Sends the appropriate command to the heat pump or AC system

Ventilation Coordination

Connects fresh-air operation with comfort and IAQ requirements

Unified System Status

Displays connected equipment and operating status in one interface

PRODUCT ARCHITECTURE & MULTI-SENSOR INTEGRATION

Integrated Heat Pump Thermostat Sensor Architecture & Onboard Multi-Sensor Platform

Unlike conventional heat pump thermostats that rely only on a single temperature element, MAXMAC can integrate temperature, humidity and optional IAQ sensing directly into the thermostat hardware. This allows the controller to make more informed HVAC decisions based on room conditions instead of temperature alone.

Structural ventilation, thermal isolation and factory calibration help reduce self-heating influence and improve data stability for long-term heat pump control.

Exploded heat pump thermostat showing touchscreen, enclosure, PCB and onboard sensors
1

4-Inch 480 × 480 dpi Full-Color Capacitive Touchscreen

2

PC+ABS, UL 94 HB Flame-Retardant Housing

3

Onboard Temperature, Humidity and Optional IAQ Sensors

4

Dual RS485, Modbus-Compatible, Optional WiFi

5

M4 Screw Fastening

KEY SENSOR ENGINEERING

MAXMAC IAQ multi-sensor development board for onboard heat pump thermostat integration

Direct PCB Onboard Integration

1

High-Precision Sensor Array

Digital temperature, humidity, CO₂, PM2.5 and TVOC sensing elements and compact modules are integrated directly with the main control PCB to form a space-efficient, multi-in-one heat pump thermostat sensor platform. Eliminating complex external probe wiring simplifies installation and helps keep the wall finish clean and uncluttered.

Explore Multi-Sensor Modules
Heat pump thermostat enclosure airflow and sensor sampling cavity design

Thermal Isolation & Structural Ventilation

2

Precision Airflow Cavity

Purpose-designed convection openings along the side and bottom of the enclosure allow room air to flow naturally through the internal heat pump thermostat sensor sampling zone. The structured airflow cavity helps isolate sensing from heat generated by internal electronics, supporting a faster response and more representative room measurements.

Multi-point heat pump thermostat sensor factory calibration curve

Factory Calibration & Real-Time Data Calibration

3

Multi-Point Factory Calibration

Every integrated heat pump thermostat sensor module is calibrated in high-precision temperature, humidity and gas calibration chambers before shipment to ensure consistent environmental data acquisition. Built-in anti-drift algorithms and ABC (Automatic Baseline Calibration) maintain stable, high-accuracy output during long-term indoor operation, supporting a design target of up to 15 years of maintenance-free operation.

THERMOSTAT PRODUCT INFORMATION

Integrated Sensor Specifications and Package Contents for Heat Pump Thermostats

Built-in Sensor Specifications

MeasurementOperating PrincipleRangeResolutionAccuracy
PM2.5Laser scattering0–999 μg/m³1 μg/m³±15 μg/m³ at ≤100; ±15% above 100
CO₂NDIR infrared400–9999 ppm1 ppm±(50 ppm + 5% of reading)
TemperatureCMOSens®−20°C to 85°C1°C±2°C
HumidityCMOSens®1–99% RH1% RH±5% RH
TVOCSemiconductor conductivity1–30,000 ppb1 ppb—

Package Contents

ItemDescriptionQuantity
1Pearl-cotton protective separator1
2Installation manual, certificate and warranty card1
3Integrated IAQ thermostat controller1
4Pearl-cotton inner tray1
5M4 × 30 mm mounting screws2
64-pin wiring terminal1
72-pin wiring terminal1
8Outer carton1
9Outer-carton label1
Exploded view of MAXMAC heat pump thermostat package contents

HEAT PUMP WIRING & INSTALLATION GUIDE

Heat Pump Thermostat Wiring Diagram

MAXMAC heat pump thermostat power and RS485 system wiring reference
WIRING REFERENCE

Power and RS485 Bus Connections

Use the terminal definitions and bus topology shown to connect the thermostat, heat pump equipment, fresh-air system, sensors and compatible smart-home systems. Each device on one RS485 network requires a unique bus address. The final wiring diagram must be confirmed against the selected thermostat model, supply voltage, heat pump control board, auxiliary or emergency heat requirements and system integration topology.

Discuss Your Heat Pump Project
1Separating the heat pump thermostat front frame from the rear assembly
STEP A

Separate the Front and Rear Assemblies

Insert a flat-head screwdriver into the lower separation slot. Support the front frame to protect the LCD and prevent it from falling, then gently pry and slowly lift the front frame away from the rear assembly.

2Heat pump thermostat power and communication terminal wiring definitions
STEP B

Complete Power and Communication Wiring

Connect the power supply, RS485 bus and required heat pump control cables to the specified terminals. Follow the project-specific wiring diagram because control boards, valves, compressors, fans, auxiliary heating and HVAC integrations may use different terminal definitions.

3Mounting the heat pump thermostat rear assembly with the sensor port facing down
STEP C

Mount the Rear Assembly in the Wall Box

Fit the rear assembly into an 86-type wall box with the sensor sampling port facing downward. Secure it to a flat wall so the integrated sensors can measure representative room conditions.

4Snapping the heat pump thermostat front frame onto the rear assembly
STEP D

Snap the Front Assembly into Place and Commission

Secure the front frame and restore power. Test heating, cooling, fan operation, communication and any auxiliary or emergency heat outputs. The installation manual must match the thermostat model, terminal definitions and final heat pump system configuration.

Installation Requirements

  1. This product must be installed by a qualified professional. Improper installation may damage the thermostat or connected heat pump equipment.
  2. Verify that the thermostat supply voltage, power rating and terminal definitions meet the project requirements.
  3. Install the thermostat approximately 1.5 meters above the floor in a well-ventilated location.

Do Not Install in the Following Locations

  • Poorly ventilated locations, including corners and behind doors.
  • Near heating or cooling pipes, direct sunlight or other heat sources.
  • Locations with unusually low or high indoor temperatures, including walls in direct contact with the outdoors.
Diagram showing unsuitable heat pump thermostat locations behind a door and in an unventilated corner

INTUITIVE MULTI-SYSTEM CONTROL

Heat Pump Thermostat Connections for HVAC Multi-System Integration

The main interface brings together air quality monitoring, fresh-air ventilation, fragrance, air conditioning and underfloor heating. Swipe left or right to move between function pages and operate the connected equipment. Available screens may vary according to the devices connected and the requirements of each project.

Wireless thermostat air quality monitoring interface showing carbon dioxide, PM2.5, temperature and humidity
Air Quality
Wireless thermostat fresh-air ventilation control interface
Fresh Air Ventilation
Wireless thermostat fragrance system control interface
Fragrance System
Wireless thermostat air-conditioning control interface
Air Conditioning
Wireless thermostat underfloor heating control interface
Underfloor Heating

Select the settings icon in the lower-left corner of the home screen to open the settings page.

Select the power icon in the lower-right corner to switch the corresponding equipment on or off. A highlighted icon indicates that the equipment is on; a dimmed icon indicates that it is off.

Open the main settings screen and select the corresponding icon to access each settings page. Use Time Settings to set the system clock, Backlight Settings to adjust LCD brightness and screen-on duration, and About to view the software version. Select More to open Engineering Configuration. This function is intended exclusively for commissioning by qualified professionals.

Wireless thermostat main settings interface with time, backlight, more and about options
Wireless thermostat system time settings interface
Wireless thermostat LCD brightness and screen-on duration settings interface

Underfloor Heating Control

The underfloor heating home screen displays the current room temperature and target temperature. Select the icon outside the temperature ring to adjust the operating settings. If the i fault icon appears, communication with the underfloor heating equipment is abnormal.

Underfloor heating home screen showing room temperature and target temperature
Underfloor heating target temperature adjustment interface

Set the Underfloor Heating Target Temperature

Fresh Air Ventilation Control

The fresh-air home screen displays the current indoor CO₂ and PM2.5 readings. Select the icons outside the ring to adjust the operating settings. If the i fault icon appears, communication with the connected fresh-air equipment is abnormal.

Fresh-air ventilation home screen showing carbon dioxide and PM2.5 readings
Ventilation operating mode icon Fresh-air ventilation operating mode selection interface
  • Smart Auto: Automatically adjusts airflow according to indoor air quality.
  • Standard Ventilation: Exchanges indoor and outdoor air directly without heat recovery.
  • Energy-Saving Fresh Air: Uses heat recovery to balance ventilation and energy efficiency.
  • Recirculation Purification: Filters recirculated indoor air without introducing outdoor air.
Fresh-air fan speed icon Fresh-air ventilation fan speed adjustment interface
  • Drag the slider to set the fan speed. In Smart Auto mode, the fan speed changes automatically.
Fresh-air zone control icon Fresh-air ventilation zone control interface
  • Zone control becomes available after the motorized air valves for each supply-air zone have been configured.
  • During installation, each air valve must use a unique RS485 address.

Fresh Air Ventilation Control — Zone Control

Zone control distributes airflow by adjusting the opening of the motorized air valve in each zone together with the total airflow supplied by the fresh-air unit. The system provides three operating modes. Both Smart and Manual modes allow unused zone valves to be switched off.

Smart Mode: Uses air-quality data and an intelligent algorithm to adjust the opening of each connected zone valve automatically.

Standard Mode: Opens each valve to the position defined during project commissioning; valve opening cannot be adjusted from this screen.

Manual Mode: Allows the user to adjust the opening of each zone valve independently.

Valve opening is adjustable from 0% to 100% (0% fully closed and 100% fully open) in 5% increments.

Smart mode fresh-air zone control interface
Standard mode fresh-air zone control interface
Manual mode fresh-air zone control interface

Air Conditioning Control

The air-conditioning home screen displays the current temperature and target temperature for the selected zone. Select the icons outside the temperature ring to adjust the operating settings. If the i fault icon appears, communication with the connected air-conditioning equipment is abnormal.

Air-conditioning home screen showing current and target zone temperature
Air-conditioning zone selection icon Air-conditioning zone selection interface

Switch the active air-supply zone to adjust the temperature and fan speed for that zone.

Air-conditioning operating mode icon Air-conditioning operating mode selection interface

Set the air-conditioning operating mode. This is a system-wide setting and applies to every zone.

Air-conditioning fan speed icon Air-conditioning fan speed selection interface

Set the air-conditioning fan speed for the selected zone.

Air-conditioning target temperature icon Air-conditioning target temperature adjustment interface

Set the target operating temperature for the selected zone.

Fragrance Control

The fragrance home screen displays the active fragrance and remaining cartridge level. Select the icons outside the fragrance ring to configure fragrance type, intensity and operating schedule. If the i fault icon appears, communication is abnormal or the fragrance cartridge has not been recognized. Replace the cartridge when the remaining level reaches 0%.

Fragrance control home screen showing active fragrance and remaining cartridge level
Fragrance type selection icon Fragrance type selection interface

Switch the active fragrance. The highlighted fragrance is active; this option applies to connected dual-channel fragrance generators.

Fragrance intensity icon Fragrance intensity selection interface

Set the fragrance intensity. Compatible single-channel equipment supports low and high output levels.

Fragrance schedule icon Fragrance timing and intermittent operation settings interface

Schedule the start time, set the operating duration for automatic shutdown, and configure the fragrance release and pause cycle for intermittent operation.

Explore Our Whole-Home Smart Fragrance Products

Engineering Configuration

Engineering Configuration is used to set device parameters and commission the controller’s RS485 network. It includes master and secondary controller panel configuration, device address assignment, zone binding and motorized air-valve zero-position calibration. This area is intended exclusively for qualified commissioning engineers and requires password verification.

Open Engineering Configuration to access detailed parameter settings. After zone air-valve configuration has been enabled, the master controller can display the opening of each motorized valve and the zone-binding list for supply-air and return-air distribution boxes. If no zone name appears in the list, the valve is not assigned to a zone and does not participate in airflow distribution.

Engineering configuration main interface
Supply-air motorized valve opening configuration interface
Return-air motorized valve opening configuration interface

If the complete list is not visible, swipe up or down to view the remaining items.

Master/Slave Setup

Select Master/Secondary Setup from Engineering Configuration to define the controller role and assign its network address.

MasterSet this controller as the master control panel and enter the number n of secondary control panels connected to it. The master then recognizes secondary-panel addresses from 48 through 47+n.

SlaveSet this controller as a secondary control panel and assign its address within the range 48 through 47+n. The corresponding panels are identified as Secondary Panel 1 through Secondary Panel n.

Engineering configuration menu interface
Master controller setup interface
Secondary controller setup interface

Recommended configuration order: Master/Secondary Setup → Local Controlled Devices → Zone Configuration (Zone Configuration → Supply-Air Motorized Distribution Box → Supply-Air Motorized Valve Setup).

Local Control Devices

Local Controlled Devices defines which fresh-air ventilation, air-conditioning, underfloor heating and fragrance equipment can be controlled from this panel. The selected configuration determines whether the corresponding function pages appear on the home interface.

Local controlled devices engineering configuration interface

Zone Smart Control Set Up

Zone Configuration is used to enable or disable individual zones, assign zone names and associate each zone with its controller panel.

After a motorized air distribution box is enabled, its connected air valves can be assigned to the corresponding terminal zones or left unassigned. The opening percentage of each valve can also be configured under standard operating conditions. The setup procedure is the same for supply-air and return-air motorized distribution boxes and their corresponding valves.

Zone smart control configuration interface for supply-air and return-air motorized distribution boxes

Air Distribution Box & Motorized Air Valve Configuration

When an air valve is set to Enabled, bind the terminal zone name for the duct connected to that valve. When it is set to Disabled, neither a zone name nor a valve-opening percentage can be assigned.

The zone-binding list for each air valve displays only the zone names that have been enabled in Zone Configuration.

— indicates that the terminal connected to an enabled valve has not been bound to a zone. The valve configuration becomes valid and its opening can be adjusted only after the zone is assigned.

Zone 9: — indicates that the connected terminal zone is enabled but has not been given a zone name. Correct the zone name and binding before commissioning.

After configuring the motorized valve opening, select New Air Valve Test to open the test screen, start the fresh-air system and verify the valve’s operation. Save the configuration for the new opening values to take effect.

Supply-air motorized distribution box valve enablement and zone configuration interface
Supply-air motorized valve zone-binding interface
Supply-air motorized valve opening-percentage configuration interface
New air valve test interface with fresh-air speed selection

WHY CHOOSE US

Why Choose MAXMAC: Pioneer in Integrated Sensor Thermostat Manufacturing

Backed by in-house engineering, testing and manufacturing capabilities, MAXMAC goes beyond the limits of conventional HVAC controllers. Integrating multi-in-one air quality sensing—including PM2.5, CO₂, TVOC, temperature and humidity—directly into a thermostat control board is not a simple matter of combining modules. It requires deep technical expertise and proven manufacturing capability. These two core advantages make MAXMAC a preferred smart thermostat partner for global OEM and ODM customers.

01

Deep Gas & IAQ Sensing Expertise

We do not simply purchase sensor assemblies and combine them with a controller. Years of in-house gas-sensor development have given MAXMAC a strong Sensor DNA. From optical NDIR algorithms and MOS semiconductor processes to complex temperature and humidity compensation, our engineers understand sensing technology at its foundation. This expertise allows us to integrate sensor circuitry closely with the thermostat main control board, address signal interference and thermal drift, and create an elegant modern thermostat that delivers accurate, stable air quality measurements over the long term.

02

In-House SMT & Rapid PCB Prototyping

Our in-house SMT production lines and engineering R&D team support the complete process from PCB design and interface customization to structural development. For individualized B2B OEM and ODM requirements, we provide rapid prototyping and efficient sample iteration. A fully controlled manufacturing chain gives us the flexibility to support both small pilot runs and high-volume delivery while offering cost-effective WiFi thermostat solutions that help customers significantly shorten time to market.

03

Flexible Thermostat Production with Full MES Traceability

MAXMAC combines automated production lines with manual assembly lines, allowing us to switch production methods flexibly according to thermostat structure, order volume and customer-specific requirements. This approach provides an efficient solution for thermostat manufacturing. Automated equipment safeguards consistency and delivery efficiency in volume production, while manual workstations support complex assembly, small-batch pilot runs and customized thermostat manufacturing.

At the same time, every production stage is connected to our MES system, enabling full MES traceability across material batches, PCB assembly, firmware programming, sensor calibration and finished thermostat inspection. This complete data trail gives customers more dependable quality-management assurance and supports reliable OEM/ODM thermostat volume delivery.

TESTING & VALIDATION

CNAS-Accredited Laboratory

MAXMAC’s CNAS-accredited laboratory brings product verification closer to our engineering and manufacturing teams, significantly shortening validation cycles and accelerating the transition from design to volume production. By identifying design weaknesses, potential failure modes, and risk-control points at an early stage, our laboratory capabilities help prevent issues before they reach customers or enter mass production.

Comprehensive mechanical, electrical, environmental, gas, and microbiological testing enables us to verify product performance under demanding operating conditions. This evidence-based validation process strengthens product stability, long-term reliability, and quality consistency while giving OEM/ODM customers greater confidence throughout development and delivery.

CNAS accreditation logo

Specialized Laboratory Facilities

  • Mechanical Reliability Testing Laboratory
  • Electrical Performance Testing Laboratory
  • Bacterial Culture Laboratory
  • Microbiological Testing Laboratory
  • Gas Testing Laboratory
  • Microbiological Inspection Laboratory
  • Balance Room
  • Precision Instrument Room
  • Ventilation Ducts Room
  • High Temperature Testing Laboratory
  • Product Aging Testing Laboratory
  • Impact Testing Laboratory
  • Salt Spray Testing Laboratory
  • Cold Chamber Laboratory
  • Vibration Testing Laboratory
Explore Our CNAS Laboratory
QUALIFICATION CERTIFICATES

Certifications and Quality Management

As a professional manufacturer of thermostats and HVAC controllers, our products come with a wide range of certifications and test reports to ensure quality, safety, and performance. These include ISO 14001, ISO 45001, ISO 9001, IATF 16949, CNAS laboratory accreditation, and more. These certifications reflect our commitment to delivering reliable thermostat and HVAC control solutions that meet global standards.

ISO 14001 Certificate
ISO 14001 Certificate
ISO 45001 Certificate
ISO 45001 Certificate
ISO 9001 Certificate
ISO 9001 Certificate
IATF 16949 Certificate
IATF 16949 Certificate
CNAS Laboratory Accreditation
CNAS Laboratory Accreditation
CNAS Laboratory Accreditation Certificate
CNAS Laboratory Accreditation Certificate

TRUSTED PARTNERS

Trusted Customers

MAXMAC supports established HVAC, thermal-management and building-technology companies with integrated sensing, thermostat controller development and OEM/ODM manufacturing services.

From product definition and PCB engineering to validation and volume delivery, our teams work closely with customers to bring reliable, connected climate-control products to market.

HVAC Brands Thermal Management OEM/ODM Partners
Carrier logo Valeo logo DENSO logo Hisense logo Honeywell logo HITACHI logo Panasonic logo YENOVA logo Habit@ logo MAHLE logo
FAQS

Frequently Asked Questions About Heat Pump Thermostats

How to wire a heat pump thermostat?

Heat pump thermostat wiring depends on the heat pump model, control board, power supply and whether auxiliary or emergency heat is required. Always confirm the terminal definition before installation.

How do heat pump thermostats work?

MAXMAC heat pump thermostats compare the target temperature with real-time room data, then send heating, cooling, fan or auxiliary-control commands according to the selected heat pump control logic.

Do heat pump thermostats have batteries?

Some models use batteries, while MAXMAC project thermostats are typically designed around wired power or project-specific power supply requirements. Battery requirements should be confirmed by model.

How to install a heat pump thermostat?

Confirm wiring, power, wall-box size, installation position and communication setup first. After wiring and mounting, run functional tests for heating, cooling, fan and any auxiliary outputs.

How to connect a heat pump thermostat?

Connection may include power, RS485, relay outputs, heat pump control terminals or gateway communication. MAXMAC can support wiring review for customized projects.

When is heat pump thermostat replacement needed?

Replacement is recommended when the old thermostat cannot match the heat pump wiring, lacks required mode control, gives unstable readings or cannot support new project functions.

What is the Minimum Order Quantity (MOQ) for B2B procurement?

Our standard Minimum Order Quantity (MOQ) for B2B heat pump thermostat procurement and volume orders is 1,000 units. Before bulk production, sample units can be supplied for engineering evaluation, function verification and project approval. Final wholesale pricing and production lead time are confirmed according to the selected specifications, customization scope and order quantity.

Do you support customization (OEM/ODM) services for bulk orders?

Yes. We provide full OEM/ODM heat pump thermostat customization for B2B bulk orders and private-label projects. Available options include communication protocols such as RS485, Modbus, WiFi, Zigbee and Ethernet; custom sensor combinations for temperature, humidity, CO₂, PM2.5 and TVOC monitoring; screen size and display-interface selection; control-board dimensions and PCB layout; enclosure structure; heating, cooling, fan, auxiliary and emergency heat control logic; logo, packaging and labeling. Our engineering team can evaluate project requirements and develop a customized thermostat platform for volume production.

Provide Your Details for Professional Product Consultation

Our product experts will provide the most suitable air solutions and product recommendations.