MAXMAC smart FCU thermostat for fan coil control

FCU THERMOSTATS

Smart FCU Thermostats Manufacturer & OEM Supplier with Integrated Multi-Sensor IAQ Platform

As a professional HVAC control and sensing solutions provider, MAXMAC supplies FCU thermostats and FCU thermostat controller solutions for fan coil unit projects worldwide. Each product integrates MAXMAC’s multi-in-one air quality sensor platform for real-time monitoring of PM2.5, CO₂, TVOC, temperature and humidity, helping customers build stable room-level control panels for their HVAC systems.

OEM/ODM customers can customize hardware, UI, control logic, sensor configuration and communication protocols according to project requirements. Production operates under strict ISO 9001 and IATF 16949 quality management systems, and our manufacturing base houses a national CNAS-accredited laboratory for environmental simulation, aging and consistency testing from the earliest stages of product development. All MAXMAC thermostat products are designed to comply with CE and RoHS requirements.

FCU THERMOSTAT SERIES

Explore Our Next-Gen Fan Coil Thermostat Series

MAXMAC provides fan coil thermostat platforms for 2-pipe, 4-pipe and project-specific fan coil unit applications. Customers can choose wired RS485 control, WiFi cloud control, programmable operation and customized UI pages according to building requirements.

6-A6312-K Wired FCU Thermostat Controller
6-A6312-K

6-A6312-K Wired FCU Thermostat Controller

Hardware
4-inch full-color touchscreen · 12V / 1A
Connectivity
Wired · RS485 · Modbus / Ethernet / ZigBee / RF expandable · No WiFi
Built-in Sensors
Temperature + Humidity

The 6-A6312-K is a wired FCU thermostat controller with built-in temperature and humidity sensors. It is suitable for fan coil unit control in hotel rooms, apartments and commercial HVAC projects where stable RS485 communication is required. The 4-inch touchscreen gives users clear access to temperature setting, fan speed and operating mode control.

Read more
6-A6316-K Wired FCU Thermostat Controller
6-A6316-K

6-A6316-K Wired FCU Thermostat Controller

Hardware
4-inch full-color touchscreen · 12V / 1A
Connectivity
Wired · RS485 · Modbus / Ethernet / ZigBee / RF expandable · No WiFi
Built-in Sensors
Temperature + Humidity

The 6-A6316-K is a wired 4-inch FCU thermostat with integrated temperature and humidity sensing. It supports RS485-based fan coil control without built-in WiFi, making it suitable for projects that need fixed wall-mounted control, stable local communication and customized FCU operation logic.

Read more
6-A6314-K WiFi + RS485 FCU Thermostat
6-A6314-K

6-A6314-K WiFi + RS485 FCU Thermostat

Hardware
4-inch full-color touchscreen · 12V / 1A
Connectivity
WiFi + RS485 · Modbus / Ethernet / ZigBee / RF expandable
Built-in Sensors
Temperature + Humidity

The 6-A6314-K combines WiFi connectivity with RS485 wired communication. With built-in temperature and humidity sensors, it can support local FCU control and remote access from one controller. It is suitable for smart fan coil thermostat projects where users need app control while keeping RS485 integration for the HVAC system. For buyers comparing fan coil thermostat WiFi options, this model combines remote access with stable RS485 HVAC integration.

Read more
6-A6313-K Wired IAQ FCU Thermostat
6-A6313-K

6-A6313-K Wired IAQ FCU Thermostat

Hardware
4-inch full-color touchscreen · 12V / 1A
Connectivity
Wired · RS485 · Modbus / Ethernet / ZigBee / RF expandable · No WiFi
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A6313-K is a wired FCU thermostat with built-in temperature, humidity, CO₂ and PM2.5 sensors. It can control fan coil operation while showing real-time indoor air quality data on the same wall panel. This model is suitable for projects that want stable wired FCU control and IAQ monitoring without relying on WiFi.

Read more
6-A6310-K Wired FCU Thermostat with IAQ Sensing
6-A6310-K

6-A6310-K Wired FCU Thermostat with IAQ Sensing

Hardware
4-inch full-color touchscreen · 12V / 1A
Connectivity
Wired · RS485 · Modbus / Ethernet / ZigBee / RF expandable · No WiFi
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A6310-K integrates temperature, humidity, CO₂ and PM2.5 sensors inside the FCU thermostat controller. It is suitable for fan coil unit systems that need room temperature control, fan-speed adjustment and indoor air quality feedback from one wired RS485 panel.

Read more
6-A6307-K Wired IAQ FCU Thermostat
6-A6307-K

6-A6307-K Wired IAQ FCU Thermostat

Hardware
4-inch full-color touchscreen · 12V / 1A
Connectivity
Wired · RS485 · Modbus / Ethernet / ZigBee / RF expandable · No WiFi
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A6307-K is a wired IAQ FCU thermostat for projects that need fixed RS485 communication and built-in environmental sensing. It monitors temperature, humidity, CO₂ and PM2.5 while supporting fan coil control, making it suitable for hotels, offices and apartment HVAC systems.

Read more
6-A6315-K WiFi + RS485 FCU Thermostat
6-A6315-K

6-A6315-K WiFi + RS485 FCU Thermostat

Hardware
4-inch full-color touchscreen · 12V / 1A
Connectivity
WiFi + RS485 · Modbus / Ethernet / ZigBee / RF expandable
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A6315-K is a smart FCU thermostat with WiFi, RS485 and built-in temperature, humidity, CO₂ and PM2.5 sensors. It supports remote access, local wired communication and real-time IAQ monitoring. This model is suitable for fan coil unit projects that need both app control and stable integration with the building HVAC system.

Read more
6-A2301-H Large-Screen Wired FCU Thermostat
6-A2301-H

6-A2301-H Large-Screen Wired FCU Thermostat

Hardware
6-inch full-color touchscreen · 12V / 1A
Connectivity
Wired · RS485 · Modbus / Ethernet / ZigBee / RF expandable · No WiFi
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A2301-H is a large-screen wired FCU thermostat with built-in temperature, humidity, CO₂ and PM2.5 sensors. Its 6-inch touchscreen gives more room for fan coil status, temperature setting and indoor air quality display. It is suitable for high-end hotel, apartment and commercial HVAC projects that require stable RS485 control.

Read more
6-A2302-H 6-Inch WiFi + RS485 FCU Thermostat
6-A2302-H

6-A2302-H 6-Inch WiFi + RS485 FCU Thermostat

Hardware
6-inch full-color touchscreen · 12V / 1A
Connectivity
WiFi + RS485 · Modbus / Ethernet / ZigBee / RF expandable
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A2302-H is a 6-inch FCU thermostat with WiFi, RS485 and built-in temperature, humidity, CO₂ and PM2.5 sensors. It is suitable for premium fan coil control projects that need a larger display, remote access and wired HVAC integration from one wall-mounted controller.

Read more
6-A5601-K Desktop FCU Thermostat
6-A5601-K

6-A5601-K Desktop FCU Thermostat

Hardware
4-inch full-color touchscreen · 3000 mAh lithium battery
Connectivity
WiFi + RS485 · Modbus not supported · Ethernet not supported
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A5601-K is a desktop FCU thermostat with built-in temperature, humidity, CO₂ and PM2.5 sensors. Its battery-powered design supports flexible placement, while WiFi and RS485 communication allow the device to work as a movable control terminal for room comfort monitoring and connected fan coil operation.

Read more

THERMOSTAT FUNCTION IN AC SYSTEMS

Thermostat Function in AC and Fan Coil Unit Systems

The thermostat function in AC systems is to measure room conditions, compare them with the target setting and send control signals to the connected air-conditioning or fan coil equipment. In an FCU system, the thermostat typically manages fan speed, valve control, operating mode and room-temperature feedback.

When integrated with MAXMAC's multi-sensor platform, the controller can also provide IAQ data such as CO2, PM2.5, TVOC, temperature and humidity, helping HVAC systems move from simple temperature control toward smarter indoor comfort management.

Room Conditions

Temperature, humidity and IAQ

FCU Thermostat

Measures the room

Control Logic

Compares feedback and setpoint

FCU Equipment

Controls fan and valve outputs

Room Comfort

Delivers stable heating or cooling

EXPLODED VIEW & SENSOR ARCHITECTURE

Integrated FCU Thermostat Sensor Architecture & Onboard Multi-Sensor Platform

MAXMAC FCU thermostats can integrate temperature, humidity and optional air-quality sensing, including PM2.5, CO₂ and TVOC, directly into the thermostat hardware. This gives the fan coil controller more reliable room data for temperature regulation and comfort optimization.

Exploded FCU thermostat showing touchscreen, enclosure, PCB and onboard sensors
1

4-Inch 480 × 480 dpi Full-Color Capacitive Touchscreen

2

PC+ABS, UL 94 HB Flame-Retardant Housing

3

Onboard Temperature, Humidity and Optional IAQ Sensors

4

Dual RS485, Modbus-Compatible, Optional WiFi

5

M4 Screw Fastening

Customize Your FCU Thermostat
MAXMAC IAQ multi-sensor development board for onboard FCU thermostat integration

Direct PCB Onboard Integration

1

High-Precision Sensor Array

Digital temperature, humidity, CO₂, PM2.5 and TVOC sensing elements and compact modules are integrated directly with the main control PCB to form a space-efficient, multi-in-one FCU thermostat sensor platform. Eliminating complex external probe wiring simplifies installation and helps keep the wall finish clean and uncluttered.

Explore Multi-Sensor Modules
Wireless thermostat enclosure airflow and sensor sampling cavity design

Thermal Isolation & Structural Ventilation

2

Precision Airflow Cavity

Purpose-designed convection openings along the side and bottom of the enclosure allow room air to flow naturally through the internal FCU thermostat sensor sampling zone. The structured airflow cavity helps isolate sensing from heat generated by internal electronics, supporting a faster response and more representative room measurements.

Multi-point FCU thermostat sensor factory calibration curve

Factory Calibration & Real-Time Data Calibration

3

Multi-Point Factory Calibration

Every integrated FCU thermostat sensor module is calibrated in high-precision temperature, humidity and gas calibration chambers before shipment to ensure consistent environmental data acquisition. Built-in anti-drift algorithms and ABC (Automatic Baseline Calibration) maintain stable, high-accuracy output during long-term indoor operation, supporting a design target of up to 15 years of maintenance-free operation.

FCU WIRING & INSTALLATION GUIDE

Fan Coil Thermostat Wiring & Setup Guide

Use the terminal definitions and RS485 bus topology shown to connect the FCU thermostat with the fan coil unit, HVAC equipment, sensors and compatible smart-home system. Each device on the same RS485 network should use a unique bus address.

For FCU projects, the wiring diagram should match the actual fan coil type and control method. The final FCU thermostat wiring diagram should match the actual fan coil type, terminal definitions and approved control method. If the project involves 2-pipe or 4-pipe fan coil units, multi-speed fan control or customized valve logic, MAXMAC can review the wiring plan and provide model-based connection guidance.

MAXMAC FCU thermostat power and RS485 system wiring reference
WIRING REFERENCE

Power and RS485 Bus Connections

Connect the approved power, RS485, fan-speed and valve terminals for the selected FCU model and control method.

1Separating the FCU thermostat front frame from the rear assembly
STEP A

Separate the Front and Rear Assemblies

Insert a flat-head screwdriver into the lower separation slot. Support the front frame to protect the LCD and prevent it from falling, then gently pry and slowly lift the front frame away from the rear assembly.

2FCU thermostat power and communication terminal wiring definitions
STEP B

Complete Power and Communication Wiring

Connect power, RS485 and required control cables to the specified terminals. Follow the project-specific FCU thermostat instructions because valves, actuators, manifold controllers and HVAC integrations may use different wiring.

3Mounting the FCU thermostat rear assembly with the sensor port facing down
STEP C

Mount the Rear Assembly in the Wall Box

Fit the rear assembly into an 86-type wall box with the sensor sampling port facing downward. Secure it to a flat wall so the sensor can measure representative room conditions.

4Snapping the FCU thermostat front frame onto the rear assembly
STEP D

Snap the Front Assembly into Place and Commission

Secure the front frame and restore power. Commission the heating and connected systems. Any FCU thermostat manual or manual PDF must match the model, terminals and final system configuration.

Installation Requirements

  1. This product must be installed by a qualified professional. Improper installation may damage the equipment.
  2. Verify that the control panel supply voltage and power rating meet the operating requirements.
  3. Install the control panel approximately 1.5 meters above the floor in a well-ventilated location.

Do Not Install in the Following Locations

  • Poorly ventilated locations, including corners and behind doors.
  • Near heating or cooling pipes, direct sunlight or other heat sources.
  • Locations with unusually low or high indoor temperatures, including walls in direct contact with the outdoors.
Diagram showing unsuitable FCU thermostat locations behind a door and in an unventilated corner

FCU CONNECTION & CONTROL LOGIC

FCU Thermostat Connection Diagram for Fan Coil Unit Integration

FCU Thermostat UI Operation Guide

The main interface brings together air quality monitoring, fresh-air ventilation, fragrance, air conditioning and underfloor heating. Swipe left or right to move between function pages and operate the connected equipment. Available screens may vary according to the devices connected and the requirements of each project.

Wireless thermostat air quality monitoring interface showing carbon dioxide, PM2.5, temperature and humidity
Air Quality
Wireless thermostat fresh-air ventilation control interface
Fresh Air Ventilation
Wireless thermostat fragrance system control interface
Fragrance System
Wireless thermostat air-conditioning control interface
Air Conditioning
Wireless thermostat underfloor heating control interface
Underfloor Heating

Select the settings icon in the lower-left corner of the home screen to open the settings page.

Select the power icon in the lower-right corner to switch the corresponding equipment on or off. A highlighted icon indicates that the equipment is on; a dimmed icon indicates that it is off.

Open the main settings screen and select the corresponding icon to access each settings page. Use Time Settings to set the system clock, Backlight Settings to adjust LCD brightness and screen-on duration, and About to view the software version. Select More to open Engineering Configuration. This function is intended exclusively for commissioning by qualified professionals.

Wireless thermostat main settings interface with time, backlight, more and about options
Wireless thermostat system time settings interface
Wireless thermostat LCD brightness and screen-on duration settings interface

Underfloor Heating Control

The underfloor heating home screen displays the current room temperature and target temperature. Select the icon outside the temperature ring to adjust the operating settings. If the i fault icon appears, communication with the underfloor heating equipment is abnormal.

Underfloor heating home screen showing room temperature and target temperature
Underfloor heating target temperature adjustment interface

Set the Underfloor Heating Target Temperature

Fresh Air Ventilation Control

The fresh-air home screen displays the current indoor CO₂ and PM2.5 readings. Select the icons outside the ring to adjust the operating settings. If the i fault icon appears, communication with the connected fresh-air equipment is abnormal.

Fresh-air ventilation home screen showing carbon dioxide and PM2.5 readings
Ventilation operating mode icon Fresh-air ventilation operating mode selection interface
  • Smart Auto: Automatically adjusts airflow according to indoor air quality.
  • Standard Ventilation: Exchanges indoor and outdoor air directly without heat recovery.
  • Energy-Saving Fresh Air: Uses heat recovery to balance ventilation and energy efficiency.
  • Recirculation Purification: Filters recirculated indoor air without introducing outdoor air.
Fresh-air fan speed icon Fresh-air ventilation fan speed adjustment interface
  • Drag the slider to set the fan speed. In Smart Auto mode, the fan speed changes automatically.
Fresh-air zone control icon Fresh-air ventilation zone control interface
  • Zone control becomes available after the motorized air valves for each supply-air zone have been configured.
  • During installation, each air valve must use a unique RS485 address.

Fresh Air Ventilation Control — Zone Control

Zone control distributes airflow by adjusting the opening of the motorized air valve in each zone together with the total airflow supplied by the fresh-air unit. The system provides three operating modes. Both Smart and Manual modes allow unused zone valves to be switched off.

Smart Mode: Uses air-quality data and an intelligent algorithm to adjust the opening of each connected zone valve automatically.

Standard Mode: Opens each valve to the position defined during project commissioning; valve opening cannot be adjusted from this screen.

Manual Mode: Allows the user to adjust the opening of each zone valve independently.

Valve opening is adjustable from 0% to 100% (0% fully closed and 100% fully open) in 5% increments.

Smart mode fresh-air zone control interface
Standard mode fresh-air zone control interface
Manual mode fresh-air zone control interface

Air Conditioning Control

The air-conditioning home screen displays the current temperature and target temperature for the selected zone. Select the icons outside the temperature ring to adjust the operating settings. If the i fault icon appears, communication with the connected air-conditioning equipment is abnormal.

Air-conditioning home screen showing current and target zone temperature
Air-conditioning zone selection icon Air-conditioning zone selection interface

Switch the active air-supply zone to adjust the temperature and fan speed for that zone.

Air-conditioning operating mode icon Air-conditioning operating mode selection interface

Set the air-conditioning operating mode. This is a system-wide setting and applies to every zone.

Air-conditioning fan speed icon Air-conditioning fan speed selection interface

Set the air-conditioning fan speed for the selected zone.

Air-conditioning target temperature icon Air-conditioning target temperature adjustment interface

Set the target operating temperature for the selected zone.

Fragrance Control

The fragrance home screen displays the active fragrance and remaining cartridge level. Select the icons outside the fragrance ring to configure fragrance type, intensity and operating schedule. If the i fault icon appears, communication is abnormal or the fragrance cartridge has not been recognized. Replace the cartridge when the remaining level reaches 0%.

Fragrance control home screen showing active fragrance and remaining cartridge level
Fragrance type selection icon Fragrance type selection interface

Switch the active fragrance. The highlighted fragrance is active; this option applies to connected dual-channel fragrance generators.

Fragrance intensity icon Fragrance intensity selection interface

Set the fragrance intensity. Compatible single-channel equipment supports low and high output levels.

Fragrance schedule icon Fragrance timing and intermittent operation settings interface

Schedule the start time, set the operating duration for automatic shutdown, and configure the fragrance release and pause cycle for intermittent operation.

Explore Our Whole-Home Smart Fragrance Products

Engineering Configuration

Engineering Configuration is used to set device parameters and commission the controller’s RS485 network. It includes master and secondary controller panel configuration, device address assignment, zone binding and motorized air-valve zero-position calibration. This area is intended exclusively for qualified commissioning engineers and requires password verification.

Open Engineering Configuration to access detailed parameter settings. After zone air-valve configuration has been enabled, the master controller can display the opening of each motorized valve and the zone-binding list for supply-air and return-air distribution boxes. If no zone name appears in the list, the valve is not assigned to a zone and does not participate in airflow distribution.

Engineering configuration main interface
Supply-air motorized valve opening configuration interface
Return-air motorized valve opening configuration interface

If the complete list is not visible, swipe up or down to view the remaining items.

Master/Slave Setup

Select Master/Secondary Setup from Engineering Configuration to define the controller role and assign its network address.

MasterSet this controller as the master control panel and enter the number n of secondary control panels connected to it. The master then recognizes secondary-panel addresses from 48 through 47+n.

SlaveSet this controller as a secondary control panel and assign its address within the range 48 through 47+n. The corresponding panels are identified as Secondary Panel 1 through Secondary Panel n.

Engineering configuration menu interface
Master controller setup interface
Secondary controller setup interface

Recommended configuration order: Master/Secondary Setup → Local Controlled Devices → Zone Configuration (Zone Configuration → Supply-Air Motorized Distribution Box → Supply-Air Motorized Valve Setup).

Local Control Devices

Local Controlled Devices defines which fresh-air ventilation, air-conditioning, underfloor heating and fragrance equipment can be controlled from this panel. The selected configuration determines whether the corresponding function pages appear on the home interface.

Local controlled devices engineering configuration interface

Zone Smart Control Set Up

Zone Configuration is used to enable or disable individual zones, assign zone names and associate each zone with its controller panel.

After a motorized air distribution box is enabled, its connected air valves can be assigned to the corresponding terminal zones or left unassigned. The opening percentage of each valve can also be configured under standard operating conditions. The setup procedure is the same for supply-air and return-air motorized distribution boxes and their corresponding valves.

Zone smart control configuration interface for supply-air and return-air motorized distribution boxes

Air Distribution Box & Motorized Air Valve Configuration

When an air valve is set to Enabled, bind the terminal zone name for the duct connected to that valve. When it is set to Disabled, neither a zone name nor a valve-opening percentage can be assigned.

The zone-binding list for each air valve displays only the zone names that have been enabled in Zone Configuration.

— indicates that the terminal connected to an enabled valve has not been bound to a zone. The valve configuration becomes valid and its opening can be adjusted only after the zone is assigned.

Zone 9: — indicates that the connected terminal zone is enabled but has not been given a zone name. Correct the zone name and binding before commissioning.

After configuring the motorized valve opening, select New Air Valve Test to open the test screen, start the fresh-air system and verify the valve’s operation. Save the configuration for the new opening values to take effect.

Supply-air motorized distribution box valve enablement and zone configuration interface
Supply-air motorized valve zone-binding interface
Supply-air motorized valve opening-percentage configuration interface
New air valve test interface with fresh-air speed selection

WHY CHOOSE US

Why Choose MAXMAC: Pioneer in Integrated Sensor Thermostat Manufacturing

Backed by in-house engineering, testing and manufacturing capabilities, MAXMAC goes beyond the limits of conventional HVAC controllers. Integrating multi-in-one air quality sensing—including PM2.5, CO₂, TVOC, temperature and humidity—directly into a thermostat control board is not a simple matter of combining modules. It requires deep technical expertise and proven manufacturing capability. These two core advantages make MAXMAC a preferred smart thermostat partner for global OEM and ODM customers.

01

Deep Gas & IAQ Sensing Expertise

We do not simply purchase sensor assemblies and combine them with a controller. Years of in-house gas-sensor development have given MAXMAC a strong Sensor DNA. From optical NDIR algorithms and MOS semiconductor processes to complex temperature and humidity compensation, our engineers understand sensing technology at its foundation. This expertise allows us to integrate sensor circuitry closely with the thermostat main control board, address signal interference and thermal drift, and create an elegant modern thermostat that delivers accurate, stable air quality measurements over the long term.

02

In-House SMT & Rapid PCB Prototyping

Our in-house SMT production lines and engineering R&D team support the complete process from PCB design and interface customization to structural development. For individualized B2B OEM and ODM requirements, we provide rapid prototyping and efficient sample iteration. A fully controlled manufacturing chain gives us the flexibility to support both small pilot runs and high-volume delivery while offering cost-effective WiFi thermostat solutions that help customers significantly shorten time to market.

03

Flexible Thermostat Production with Full MES Traceability

MAXMAC combines automated production lines with manual assembly lines, allowing us to switch production methods flexibly according to thermostat structure, order volume and customer-specific requirements. This approach provides an efficient solution for thermostat manufacturing. Automated equipment safeguards consistency and delivery efficiency in volume production, while manual workstations support complex assembly, small-batch pilot runs and customized thermostat manufacturing.

At the same time, every production stage is connected to our MES system, enabling full MES traceability across material batches, PCB assembly, firmware programming, sensor calibration and finished thermostat inspection. This complete data trail gives customers more dependable quality-management assurance and supports reliable OEM/ODM thermostat volume delivery.

TESTING & VALIDATION

CNAS-Accredited Laboratory

MAXMAC’s CNAS-accredited laboratory brings product verification closer to our engineering and manufacturing teams, significantly shortening validation cycles and accelerating the transition from design to volume production. By identifying design weaknesses, potential failure modes, and risk-control points at an early stage, our laboratory capabilities help prevent issues before they reach customers or enter mass production.

Comprehensive mechanical, electrical, environmental, gas, and microbiological testing enables us to verify product performance under demanding operating conditions. This evidence-based validation process strengthens product stability, long-term reliability, and quality consistency while giving OEM/ODM customers greater confidence throughout development and delivery.

CNAS accreditation logo

Specialized Laboratory Facilities

  • Mechanical Reliability Testing Laboratory
  • Electrical Performance Testing Laboratory
  • Bacterial Culture Laboratory
  • Microbiological Testing Laboratory
  • Gas Testing Laboratory
  • Microbiological Inspection Laboratory
  • Balance Room
  • Precision Instrument Room
  • Ventilation Ducts Room
  • High Temperature Testing Laboratory
  • Product Aging Testing Laboratory
  • Impact Testing Laboratory
  • Salt Spray Testing Laboratory
  • Cold Chamber Laboratory
  • Vibration Testing Laboratory
Explore Our CNAS Laboratory
QUALIFICATION CERTIFICATES

Certifications and Quality Management

As a professional manufacturer of thermostats and HVAC controllers, our products come with a wide range of certifications and test reports to ensure quality, safety, and performance. These include ISO 14001, ISO 45001, ISO 9001, IATF 16949, CNAS laboratory accreditation, and more. These certifications reflect our commitment to delivering reliable thermostat and HVAC control solutions that meet global standards.

ISO 14001 Certificate
ISO 14001 Certificate
ISO 45001 Certificate
ISO 45001 Certificate
ISO 9001 Certificate
ISO 9001 Certificate
IATF 16949 Certificate
IATF 16949 Certificate
CNAS Laboratory Accreditation
CNAS Laboratory Accreditation
CNAS Laboratory Accreditation Certificate
CNAS Laboratory Accreditation Certificate

TRUSTED PARTNERS

Trusted Customers

MAXMAC supports established HVAC, thermal-management and building-technology companies with integrated sensing, thermostat controller development and OEM/ODM manufacturing services.

From product definition and PCB engineering to validation and volume delivery, our teams work closely with customers to bring reliable, connected climate-control products to market.

HVAC Brands Thermal Management OEM/ODM Partners
Carrier logo Valeo logo DENSO logo Hisense logo Honeywell logo HITACHI logo Panasonic logo YENOVA logo Habit@ logo MAHLE logo
FAQS

Frequently Asked Questions About FCU Thermostats

What is the hold setting on a thermostat?

Hold keeps the thermostat at a selected target temperature or mode instead of following the normal schedule. Availability depends on the programmed UI and control logic.

What is X2 on a thermostat?

X2 is often used as an auxiliary or second-stage heating terminal in some HVAC wiring systems, but the meaning depends on the equipment manufacturer. Confirm the terminal definition before wiring.

Do all thermostats have a C wire?

No. Some thermostats require a common wire for continuous power, while others use different power designs. FCU projects should confirm power supply and wiring before selecting a controller.

What is a 3 heat 2 cool thermostat?

It refers to a thermostat that can support three heating stages and two cooling stages. Whether this is needed depends on the HVAC equipment and control strategy.

What is the Minimum Order Quantity (MOQ) for B2B FCU thermostat procurement?

Our standard Minimum Order Quantity for B2B FCU thermostat procurement and volume orders is 1,000 units. Final MOQ, pricing and production lead time are confirmed according to the selected model, fan coil control requirements, communication protocol, sensor configuration, customization scope and order quantity.

Can we order FCU thermostat samples before bulk production?

Yes. Sample units can be supplied for engineering evaluation, functional testing, wiring and communication compatibility testing, and project approval before volume production. Sample availability, configuration, cost and preparation time depend on the selected model and customization requirements.

Does MAXMAC support OEM/ODM customization for bulk FCU thermostat orders?

Yes. MAXMAC provides OEM/ODM customization for B2B bulk orders and private-label projects. Available options include enclosure colors, logo printing, user-interface design, sensor configurations, WiFi, RS485 and Modbus communication, software control logic, packaging and labeling. Our engineering team can evaluate project requirements and develop a customized FCU thermostat platform for volume production.

Can FCU thermostat relay outputs and control logic be customized?

Yes. MAXMAC can customize fan-speed relay outputs, 2-pipe and 4-pipe fan coil control, heating and cooling valve outputs, operating modes, changeover logic, interlocks and project-specific control sequences. Final relay ratings, terminal definitions and control logic are confirmed according to the connected fan coil equipment and approved wiring design.

Provide Your Details for Professional Product Consultation

Our product experts will provide the most suitable air solutions and product recommendations.