MAXMAC boiler thermostat for connected room heating and IAQ control

Boiler Thermostat

Smart Boiler Thermostat Manufacturer & OEM Supplier with Integrated Multi-Sensor IAQ Platform

As a professional HVAC control and sensing solutions provider, MAXMAC supplies next-generation smart boiler thermostat solutions to customers worldwide. More than an efficient thermostat for boiler heating systems, each product integrates the MAXMAC multi-in-one air quality sensor platform for real-time monitoring of PM2.5, CO₂, TVOC, temperature and humidity. One device enables unified smart control of wall-hung boilers and conventional boilers, air conditioning, fresh-air ventilation, underfloor heating and fragrance systems throughout the home.

Production operates under strict ISO 9001 and IATF 16949 quality management systems, and our manufacturing base houses a national CNAS-accredited standard laboratory for environmental simulation, aging and consistency testing from the earliest stages of product development. All MAXMAC thermostat products fully comply with CE and RoHS requirements. We provide reliable, high-performance OEM/ODM solutions that help customers lead the smart environmental control market.

SMART BOILER THERMOSTAT SERIES

Explore Our Next-Gen Smart Boiler Thermostats

6-A6312-K wired digital boiler thermostat
6-A6312-K

6-A6312-K Wired Digital Boiler Thermostat

Hardware
4-inch full-color touchscreen
Connectivity
Wired · RS485 · Modbus / Ethernet expandable · No WiFi
Built-in Sensors
Temperature + Humidity

The 6-A6312-K is a wired digital boiler thermostat built around RS485 bus communication. It features a 4-inch HD full-color touchscreen and high-precision temperature and humidity sensors. Designed as a room-level HVAC control hub, it provides precise wall-hung boiler heating control while coordinating central air conditioning, fresh-air ventilation, underfloor heating and fragrance systems from one interface—an ideal boiler thermostat for residential heating projects.

Read more
6-A6314-K wireless smart boiler thermostat
6-A6314-K

6-A6314-K Wireless Smart Boiler Thermostat

Hardware
4-inch full-color touchscreen
Connectivity
Wireless + Wired · WiFi + RS485 · Modbus / Ethernet expandable
Built-in Sensors
Temperature + Humidity

The 6-A6314-K combines WiFi cloud connectivity with wired RS485 bus communication to create a highly intelligent WiFi boiler thermostat. Its 4-inch full-color touchscreen and integrated temperature and humidity sensing support remote app-based boiler heating adjustment, while one device coordinates air conditioning, fresh-air ventilation, underfloor heating and fragrance systems.

Read more
6-A6313-K wired programmable boiler thermostat
6-A6313-K

6-A6313-K Wired Programmable Boiler Thermostat

Hardware
4-inch full-color touchscreen
Connectivity
Wired · RS485 · Modbus / Ethernet expandable · No WiFi
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A6313-K is a programmable boiler thermostat with integrated CO₂, PM2.5, temperature and humidity sensing. Its wired RS485 connection enables precise scheduled boiler temperature control, while real-time air quality data supports coordinated operation of the boiler, fresh-air ventilation, air conditioning, underfloor heating and fragrance systems. It is an energy-efficient boiler room thermostat for integrated room control.

Read more
6-A6310-K wired boiler room thermostat
6-A6310-K

6-A6310-K Wired Boiler Room Thermostat

Hardware
4-inch full-color touchscreen
Connectivity
Wired · RS485 · Modbus / Ethernet expandable · No WiFi
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

Engineered to integrate indoor environmental health with heating control, the 6-A6310-K boiler room thermostat uses wired RS485 bus communication and onboard CO₂, PM2.5, temperature and humidity sensors. As a system-level control hub, one device seamlessly coordinates the wall-hung boiler, air conditioning, fresh-air ventilation, underfloor heating and fragrance equipment.

Read more
6-A6315-K wireless universal boiler thermostat
6-A6315-K

6-A6315-K Wireless Universal Boiler Thermostat

Connectivity
Wireless + Wired · WiFi + RS485 · Modbus / Ethernet expandable
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A6315-K combines WiFi networking and wired RS485 connectivity with integrated CO₂, PM2.5, temperature and humidity sensors. This fully equipped smart boiler thermostat supports remote cloud control and serves as a universal boiler thermostat capable of coordinating the boiler, air conditioning, fresh-air ventilation, underfloor heating and fragrance systems from one device.

Read more
6-A2301-H large-screen universal boiler thermostat
6-A2301-H

6-A2301-H Large-Screen Universal Boiler Thermostat

Hardware
6-inch full-color touchscreen
Connectivity
Wired · RS485 · Modbus / Ethernet expandable · No WiFi
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A2301-H pairs a luxurious 6-inch full-color touchscreen with wired RS485 bus connectivity. As a universal boiler thermostat, it integrates CO₂, PM2.5, temperature and humidity sensing with unified control of the boiler, air conditioning, fresh-air ventilation, underfloor heating and fragrance systems, making it well suited to luxury residential projects.

Read more
6-A2302-H 6-inch digital boiler thermostat
6-A2302-H

6-A2302-H 6-Inch Digital Boiler Thermostat

Hardware
6-inch full-color touchscreen
Connectivity
Wireless + Wired · WiFi + RS485 · Modbus / Ethernet expandable
Built-in Sensors
Temperature + Humidity + CO₂ + PM2.5

The 6-A2302-H is a digital boiler thermostat with an expansive 6-inch full-color touchscreen, wired RS485 communication and a WiFi wireless module. Integrated CO₂, PM2.5, temperature and humidity sensing supports centralized, one-stop control of boiler heating, air conditioning, fresh-air ventilation, underfloor heating and fragrance systems.

Read more

SMART HEATING CONTROL LOGIC

Smart Boiler Thermostat Setting for Optimized Heating Control

At the heart of intelligent boiler control is the precise detection of indoor temperature and the automatic adjustment of heating operation as environmental conditions change. Using a built-in high-precision boiler thermostat sensor, the smart thermostat continuously monitors room-temperature fluctuations and sends the measured data to its control algorithm for analysis.

When the actual room temperature falls below the target setting, the thermostat signals the boiler system to start hot-water circulation and deliver heat to hydronic underfloor heating, radiators and other heating equipment. Once the room reaches the target temperature, the system automatically reduces or stops heating, balancing indoor comfort with energy efficiency.

Temperature Sensor Detects room temperature
Smart Boiler Thermostat Analyzes the target setting
Boiler Heating System Adjusts heat delivery
Indoor Temperature Adjustment Balances comfort and efficiency

INTEGRATED SENSOR ARCHITECTURE

Integrated Boiler Thermostat Sensor Architecture & Onboard Multi-Sensor Platform

Unlike conventional devices that rely on external probes or a single temperature-sensing element, MAXMAC uses a highly integrated onboard design that embeds an advanced boiler thermostat sensor platform directly into the thermostat main PCB and engineered enclosure. This architecture enables precise, real-time monitoring of the indoor environment without adding separate wall-mounted sensing hardware.

Exploded MAXMAC boiler thermostat showing the display, PCB, onboard multi-sensor platform and engineered enclosure
1

4-Inch 480 × 480 dpi Full-Color Capacitive LCD Touchscreen

5

M4 Screw Fastening

2

PC+ABS, UL 94 HB Flame-Retardant Housing

3

MAXMAC IAQ Multi-Sensor (PM + CO₂ + Temperature & Humidity + Expandable TVOC)

4

Dual RS485, Modbus-Compatible, Optional WiFi

Customize Your Thermostat

KEY SENSOR ENGINEERING

MAXMAC IAQ multi-sensor development board for onboard boiler thermostat integration

Direct PCB Onboard Integration

1

High-Precision Sensor Array

Digital temperature, humidity, CO₂, PM2.5 and TVOC sensing elements and compact modules are integrated directly with the main control PCB to form a space-efficient, multi-in-one boiler thermostat sensor platform. Eliminating complex external probe wiring simplifies installation and helps keep the wall finish clean and uncluttered.

Explore Multi-Sensor Modules
Boiler thermostat enclosure airflow and sensor sampling cavity design

Thermal Isolation & Structural Ventilation

2

Precision Airflow Cavity

Purpose-designed convection openings along the side and bottom of the enclosure allow room air to flow naturally through the internal boiler thermostat sensor sampling zone. The structured airflow cavity helps isolate sensing from heat generated by internal electronics, supporting a faster response and more representative room measurements.

Multi-point boiler thermostat sensor factory calibration curve

Factory Calibration & Real-Time Data Calibration

3

Multi-Point Factory Calibration

Every integrated boiler thermostat sensor module is calibrated in high-precision temperature, humidity and gas calibration chambers before shipment to ensure consistent environmental data acquisition. Built-in anti-drift algorithms and ABC (Automatic Baseline Calibration) maintain stable, high-accuracy output during long-term indoor operation, supporting a design target of up to 15 years of maintenance-free operation.

THERMOSTAT PRODUCT INFORMATION

Integrated Sensor Specifications and Package Contents for Boiler Thermostats

Built-in Sensor Specifications

Measurement Operating Principle Range Resolution Accuracy
PM2.5Laser scattering0–999 μg/m³1 μg/m³±15 μg/m³ at ≤100; ±15% above 100
CO₂NDIR infrared400–9999 ppm1 ppm±(50 ppm + 5% of reading)
TemperatureCMOSens®−20°C to 85°C1°C±2°C
HumidityCMOSens®1–99% RH1% RH±5% RH
TVOCSemiconductor conductivity1–30,000 ppb1 ppb—

Package Contents

ItemDescriptionQuantity
1Pearl-cotton protective separator1
2Installation manual, certificate and warranty card1
3Integrated IAQ thermostat controller1
4Pearl-cotton inner tray1
5M4 × 30 mm mounting screws2
64-pin wiring terminal1
72-pin wiring terminal1
8Outer carton1
9Outer-carton label1
Exploded view of MAXMAC boiler thermostat package contents

BOILER WIRING & INSTALLATION GUIDE

Boiler Thermostat Wiring & Setup Guide

MAXMAC thermostat power and RS485 system wiring reference
WIRING REFERENCE

Power and RS485 Bus Connections

Use the terminal definitions and bus topology shown to connect the controller, HVAC equipment, sensors and compatible smart-home systems. Each device on the same RS485 network must use a unique bus address.

Discuss Your Thermostat Project
1Separating the thermostat front frame from the rear cover assembly
STEP A

Separate the Front and Rear Assemblies

Insert a flat-head screwdriver into the separation slot on the bottom or lower side. Support the front frame with one hand to protect the LCD and prevent it from falling, then gently pry and slowly lift the front frame to separate the front and rear assemblies.

2Thermostat power and communication terminal wiring definitions
STEP B

Complete Power and Communication Wiring

Following the controller wiring definitions, connect the power cable and communication lines to the specified terminals in sequence.

3Mounting the thermostat rear assembly in a wall box with the sensor sampling port facing down
STEP C

Mount the Rear Assembly in the Wall Box

Place the controller rear assembly in an 86-type wall box with the sensor sampling port facing downward. Ensure the wall surface is flat, then secure the assembly with screws.

4Snapping the thermostat front frame securely onto the rear assembly
STEP D

Snap the Front Assembly into Place and Commission

Snap the front frame securely onto the rear assembly and switch on the power. After the LCD illuminates, proceed with commissioning of the controlled equipment.

Recommended Installation Location for Accurate Temperature Detection

To ensure that a boiler thermostat accurately detects indoor environmental conditions, its installation location is critical to effective system control.

The built-in boiler thermostat sensor should be installed where it can represent the overall room temperature, without being affected by localized heat or cold sources. Accurate temperature acquisition enables the thermostat to send more precise control signals to the boiler system and intelligently regulate when the heating equipment starts and stops.

Recommended controller locations:

  • On an interior wall approximately 1.5 meters above the floor.
  • In an area with natural airflow that reflects the average room temperature.
  • Away from sources of hot or cold interference.

Avoid installing the controller in these locations:

  • In direct sunlight.
  • Near radiators, boilers, hot-water pipes or other heat sources.
  • Near air-conditioning outlets or fresh-air supply vents.
  • Behind doors, in corners or in other areas with weak airflow.
  • On walls in direct contact with the outdoors.
Recommended and unsuitable boiler thermostat installation locations around doors, corners and exterior walls

INTUITIVE MULTI-SYSTEM CONTROL

Advanced Boiler Thermostat Control: Precision Heating & HVAC Multi-System Integration

The main interface brings together air quality monitoring, fresh-air ventilation, fragrance, air conditioning and underfloor heating. Swipe left or right to move between function pages and operate the connected equipment. Available screens may vary according to the devices connected and the requirements of each project.

Boiler thermostat air quality monitoring interface showing carbon dioxide, PM2.5, temperature and humidity
Air Quality
Boiler thermostat fresh-air ventilation control interface
Fresh Air Ventilation
Boiler thermostat fragrance system control interface
Fragrance System
Boiler thermostat air-conditioning control interface
Air Conditioning
Boiler thermostat underfloor heating control interface
Underfloor Heating

Select the settings icon in the lower-left corner of the home screen to open the settings page.

Select the power icon in the lower-right corner to switch the corresponding equipment on or off. A highlighted icon indicates that the equipment is on; a dimmed icon indicates that it is off.

Open the main settings screen and select the corresponding icon to access each settings page. Use Time Settings to set the system clock, Backlight Settings to adjust LCD brightness and screen-on duration, and About to view the software version. Select More to open Engineering Configuration. This function is intended exclusively for commissioning by qualified professionals.

Boiler thermostat main settings interface with time, backlight, more and about options
Boiler thermostat system time settings interface
Boiler thermostat LCD brightness and screen-on duration settings interface

Underfloor Heating Control

The underfloor heating home screen displays the current room temperature and target temperature. Select the icon outside the temperature ring to adjust the operating settings. If the i fault icon appears, communication with the underfloor heating equipment is abnormal.

Underfloor heating home screen showing room temperature and target temperature
Underfloor heating target temperature adjustment interface

Set the Underfloor Heating Target Temperature

Fresh Air Ventilation Control

The fresh-air home screen displays the current indoor CO₂ and PM2.5 readings. Select the icons outside the ring to adjust the operating settings. If the i fault icon appears, communication with the connected fresh-air equipment is abnormal.

Fresh-air ventilation home screen showing carbon dioxide and PM2.5 readings
Ventilation operating mode icon Fresh-air ventilation operating mode selection interface
  • Smart Auto: Automatically adjusts airflow according to indoor air quality.
  • Standard Ventilation: Exchanges indoor and outdoor air directly without heat recovery.
  • Energy-Saving Fresh Air: Uses heat recovery to balance ventilation and energy efficiency.
  • Recirculation Purification: Filters recirculated indoor air without introducing outdoor air.
Fresh-air fan speed icon Fresh-air ventilation fan speed adjustment interface
  • Drag the slider to set the fan speed. In Smart Auto mode, the fan speed changes automatically.
Fresh-air zone control icon Fresh-air ventilation zone control interface
  • Zone control becomes available after the motorized air valves for each supply-air zone have been configured.
  • During installation, each air valve must use a unique RS485 address.

Fresh Air Ventilation Control — Zone Control

Zone control distributes airflow by adjusting the opening of the motorized air valve in each zone together with the total airflow supplied by the fresh-air unit. The system provides three operating modes. Both Smart and Manual modes allow unused zone valves to be switched off.

Smart Mode: Uses air-quality data and an intelligent algorithm to adjust the opening of each connected zone valve automatically.

Standard Mode: Opens each valve to the position defined during project commissioning; valve opening cannot be adjusted from this screen.

Manual Mode: Allows the user to adjust the opening of each zone valve independently.

Valve opening is adjustable from 0% to 100% (0% fully closed and 100% fully open) in 5% increments.

Smart mode fresh-air zone control interface
Standard mode fresh-air zone control interface
Manual mode fresh-air zone control interface

Air Conditioning Control

The air-conditioning home screen displays the current temperature and target temperature for the selected zone. Select the icons outside the temperature ring to adjust the operating settings. If the i fault icon appears, communication with the connected air-conditioning equipment is abnormal.

Air-conditioning home screen showing current and target zone temperature
Air-conditioning zone selection icon Air-conditioning zone selection interface

Switch the active air-supply zone to adjust the temperature and fan speed for that zone.

Air-conditioning operating mode icon Air-conditioning operating mode selection interface

Set the air-conditioning operating mode. This is a system-wide setting and applies to every zone.

Air-conditioning fan speed icon Air-conditioning fan speed selection interface

Set the air-conditioning fan speed for the selected zone.

Air-conditioning target temperature icon Air-conditioning target temperature adjustment interface

Set the target operating temperature for the selected zone.

Fragrance Control

The fragrance home screen displays the active fragrance and remaining cartridge level. Select the icons outside the fragrance ring to configure fragrance type, intensity and operating schedule. If the i fault icon appears, communication is abnormal or the fragrance cartridge has not been recognized. Replace the cartridge when the remaining level reaches 0%.

Fragrance control home screen showing active fragrance and remaining cartridge level
Fragrance type selection icon Fragrance type selection interface

Switch the active fragrance. The highlighted fragrance is active; this option applies to connected dual-channel fragrance generators.

Fragrance intensity icon Fragrance intensity selection interface

Set the fragrance intensity. Compatible single-channel equipment supports low and high output levels.

Fragrance schedule icon Fragrance timing and intermittent operation settings interface

Schedule the start time, set the operating duration for automatic shutdown, and configure the fragrance release and pause cycle for intermittent operation.

Explore Our Whole-Home Smart Fragrance Products

Engineering Configuration

Engineering Configuration is used to set device parameters and commission the controller’s RS485 network. It includes master and secondary controller panel configuration, device address assignment, zone binding and motorized air-valve zero-position calibration. This area is intended exclusively for qualified commissioning engineers and requires password verification.

Open Engineering Configuration to access detailed parameter settings. After zone air-valve configuration has been enabled, the master controller can display the opening of each motorized valve and the zone-binding list for supply-air and return-air distribution boxes. If no zone name appears in the list, the valve is not assigned to a zone and does not participate in airflow distribution.

Engineering configuration main interface
Supply-air motorized valve opening configuration interface
Return-air motorized valve opening configuration interface

If the complete list is not visible, swipe up or down to view the remaining items.

Master/Slave Setup

Select Master/Secondary Setup from Engineering Configuration to define the controller role and assign its network address.

MasterSet this controller as the master control panel and enter the number n of secondary control panels connected to it. The master then recognizes secondary-panel addresses from 48 through 47+n.

SlaveSet this controller as a secondary control panel and assign its address within the range 48 through 47+n. The corresponding panels are identified as Secondary Panel 1 through Secondary Panel n.

Engineering configuration menu interface
Master controller setup interface
Secondary controller setup interface

Recommended configuration order: Master/Secondary Setup → Local Controlled Devices → Zone Configuration (Zone Configuration → Supply-Air Motorized Distribution Box → Supply-Air Motorized Valve Setup).

Local Control Devices

Local Controlled Devices defines which fresh-air ventilation, air-conditioning, underfloor heating and fragrance equipment can be controlled from this panel. The selected configuration determines whether the corresponding function pages appear on the home interface.

Local controlled devices engineering configuration interface

Zone Smart Control Set Up

Zone Configuration is used to enable or disable individual zones, assign zone names and associate each zone with its controller panel.

After a motorized air distribution box is enabled, its connected air valves can be assigned to the corresponding terminal zones or left unassigned. The opening percentage of each valve can also be configured under standard operating conditions. The setup procedure is the same for supply-air and return-air motorized distribution boxes and their corresponding valves.

Zone smart control configuration interface for supply-air and return-air motorized distribution boxes

Zone Configuration

The Zone Configuration interface uses Enabled and Disabled to control each zone, assign its name and bind it to the appropriate controller panel. When the same zone name is used for multiple areas, add a numeric suffix x so each area is identified as Name_x, for example, Aisle_1.

Zone binding can be configured only from the Master controller. By default, the master controller is bound to Zone 1, with the zone set to Enabled. Installing the master controller in a shared area is recommended for easier system management. The controller-panel list is generated dynamically according to the number of secondary controllers defined in the master/secondary configuration.

— indicates that an enabled zone has not yet been given a zone name or assigned to a secondary controller. Every enabled zone must be named; a zone without its own controller panel can remain unbound.

Zone enablement, naming and controller-panel binding interface
Zone name selection and numeric suffix configuration interface
Zone controller-panel binding selection interface

Air Distribution Box & Motorized Air Valve Configuration

When an air valve is set to Enabled, bind the terminal zone name for the duct connected to that valve. When it is set to Disabled, neither a zone name nor a valve-opening percentage can be assigned.

The zone-binding list for each air valve displays only the zone names that have been enabled in Zone Configuration.

— indicates that the terminal connected to an enabled valve has not been bound to a zone. The valve configuration becomes valid and its opening can be adjusted only after the zone is assigned.

Zone 9: — indicates that the connected terminal zone is enabled but has not been given a zone name. Correct the zone name and binding before commissioning.

After configuring the motorized valve opening, select New Air Valve Test to open the test screen, start the fresh-air system and verify the valve’s operation. Save the configuration for the new opening values to take effect.

Supply-air motorized distribution box valve enablement and zone configuration interface
Supply-air motorized valve zone-binding interface
Supply-air motorized valve opening-percentage configuration interface
New air valve test interface with fresh-air speed selection

WHY CHOOSE US

Why Choose MAXMAC: Pioneer in Integrated Sensor Thermostat Manufacturing

Backed by in-house engineering, testing and manufacturing capabilities, MAXMAC goes beyond the limits of conventional HVAC controllers. Integrating multi-in-one air quality sensing—including PM2.5, CO₂, TVOC, temperature and humidity—directly into a thermostat control board is not a simple matter of combining modules. It requires deep technical expertise and proven manufacturing capability. These two core advantages make MAXMAC a preferred smart thermostat partner for global OEM and ODM customers.

01

Deep Gas & IAQ Sensing Expertise

We do not simply purchase sensor assemblies and combine them with a controller. Years of in-house gas-sensor development have given MAXMAC a strong Sensor DNA. From optical NDIR algorithms and MOS semiconductor processes to complex temperature and humidity compensation, our engineers understand sensing technology at its foundation. This expertise allows us to integrate sensor circuitry closely with the thermostat main control board, address signal interference and thermal drift, and create an elegant modern thermostat that delivers accurate, stable air quality measurements over the long term.

02

In-House SMT & Rapid PCB Prototyping

Our in-house SMT production lines and engineering R&D team support the complete process from PCB design and interface customization to structural development. For individualized B2B OEM and ODM requirements, we provide rapid prototyping and efficient sample iteration. A fully controlled manufacturing chain gives us the flexibility to support both small pilot runs and high-volume delivery while offering cost-effective WiFi thermostat solutions that help customers significantly shorten time to market.

03

Flexible Thermostat Production with Full MES Traceability

MAXMAC combines automated production lines with manual assembly lines, allowing us to switch production methods flexibly according to thermostat structure, order volume and customer-specific requirements. This approach provides an efficient solution for thermostat manufacturing. Automated equipment safeguards consistency and delivery efficiency in volume production, while manual workstations support complex assembly, small-batch pilot runs and customized thermostat manufacturing.

At the same time, every production stage is connected to our MES system, enabling full MES traceability across material batches, PCB assembly, firmware programming, sensor calibration and finished thermostat inspection. This complete data trail gives customers more dependable quality-management assurance and supports reliable OEM/ODM thermostat volume delivery.

TESTING & VALIDATION

CNAS-Accredited Laboratory

MAXMAC’s CNAS-accredited laboratory brings product verification closer to our engineering and manufacturing teams, significantly shortening validation cycles and accelerating the transition from design to volume production. By identifying design weaknesses, potential failure modes, and risk-control points at an early stage, our laboratory capabilities help prevent issues before they reach customers or enter mass production.

Comprehensive mechanical, electrical, environmental, gas, and microbiological testing enables us to verify product performance under demanding operating conditions. This evidence-based validation process strengthens product stability, long-term reliability, and quality consistency while giving OEM/ODM customers greater confidence throughout development and delivery.

CNAS accreditation logo

Specialized Laboratory Facilities

  • Mechanical Reliability Testing Laboratory
  • Electrical Performance Testing Laboratory
  • Bacterial Culture Laboratory
  • Microbiological Testing Laboratory
  • Gas Testing Laboratory
  • Microbiological Inspection Laboratory
  • Balance Room
  • Precision Instrument Room
  • Ventilation Ducts Room
  • High Temperature Testing Laboratory
  • Product Aging Testing Laboratory
  • Impact Testing Laboratory
  • Salt Spray Testing Laboratory
  • Cold Chamber Laboratory
  • Vibration Testing Laboratory
Explore Our CNAS Laboratory
QUALIFICATION CERTIFICATES

Certifications and Quality Management

As a professional manufacturer of thermostats and HVAC controllers, our products come with a wide range of certifications and test reports to ensure quality, safety, and performance. These include ISO 14001, ISO 45001, ISO 9001, IATF 16949, CNAS laboratory accreditation, and more. These certifications reflect our commitment to delivering reliable thermostat and HVAC control solutions that meet global standards.

ISO 14001 Certificate
ISO 14001 Certificate
ISO 45001 Certificate
ISO 45001 Certificate
ISO 9001 Certificate
ISO 9001 Certificate
IATF 16949 Certificate
IATF 16949 Certificate
CNAS Laboratory Accreditation
CNAS Laboratory Accreditation
CNAS Laboratory Accreditation Certificate
CNAS Laboratory Accreditation Certificate

TRUSTED PARTNERS

Trusted Customers

MAXMAC supports established HVAC, thermal-management and building-technology companies with integrated sensing, thermostat controller development and OEM/ODM manufacturing services.

From product definition and PCB engineering to validation and volume delivery, our teams work closely with customers to bring reliable, connected climate-control products to market.

HVAC Brands Thermal Management OEM/ODM Partners
Carrier logo Valeo logo DENSO logo Hisense logo Honeywell logo HITACHI logo Panasonic logo YENOVA logo Habit@ logo MAHLE logo
FAQS

Frequently Asked Questions About Boiler Thermostats

Can a boiler work without a thermostat?

Yes. A boiler can operate through its built-in manual controls without a room thermostat, but temperature regulation will be less precise. This can cause overheating, unnecessary energy consumption and additional wear on the heating system. Installing a smart boiler thermostat is recommended for better comfort and energy efficiency.

How do I reset a boiler thermostat when the connection drops?

Follow the reset procedure specified for your thermostat model. This commonly involves holding the system reset button for five seconds or safely isolating the power supply briefly before restarting the controller. A reset may restore the WiFi or RS485 communication link. Always consult the boiler thermostat manual and use a qualified installer when electrical access is required.

When should you consider a replacement boiler thermostat?

Consider a replacement boiler thermostat when the existing controller is outdated, unresponsive, inaccurate or incompatible with the required heating system. A modern replacement with integrated IAQ sensors and multi-system control can improve temperature regulation, indoor air quality monitoring and overall heating performance.

What should I do if my boiler thermostat is not working properly?

If a boiler thermostat is not working properly, first check the power supply, terminal wiring, sensor calibration and relay signal output. Confirm that the dry-contact output and control voltage match the boiler’s requirements. If the issue continues, have the wiring and controller inspected by a qualified technician.

Why is my boiler not connecting to the thermostat?

A boiler may fail to connect to its thermostat when the RS485 or relay wiring is loose, the device addresses do not match, or the WiFi pairing is inactive. Verify the signal cables, communication settings and wireless channel, then follow the model-specific manual for connection troubleshooting.

What is the Minimum Order Quantity (MOQ) for B2B procurement?

Our standard Minimum Order Quantity (MOQ) for B2B boiler thermostat procurement and volume orders is 1,000 units. Before bulk production, sample units can be supplied for engineering evaluation, function verification and project approval. Final wholesale pricing and production lead time are confirmed according to the selected specifications, customization scope and order quantity.

Do you support customization (OEM/ODM) services for bulk orders?

Yes. We provide full OEM/ODM boiler thermostat customization for B2B bulk orders and private-label projects. Available options include communication protocols such as RS485, Modbus, Wi-Fi, Zigbee and Ethernet; custom sensor combinations for temperature, humidity, CO₂, PM2.5 and TVOC monitoring; screen size and display-interface selection; control-board dimensions and PCB layout; enclosure structure; software control logic; logo, packaging and labeling. Our engineering team can evaluate project requirements and develop a customized thermostat platform for volume production.

Provide Your Details for Professional Product Consultation

Our product experts will provide the most suitable air solutions and product recommendations.