A54-21 PM2.5 Sensor
Dedicated particulate sensing node for ventilation cleanliness, filter-performance evaluation and indoor air quality monitoring. It supports RS485 and UART interfaces, with expandable Modbus protocol support.
Read more
INDOOR AIR QUALITY SENSORS
As a professional indoor air quality sensor manufacturer, MAXMAC supplies high-quality indoor air quality sensor products and customizable IAQ multi sensor solutions to HVAC system manufacturers, smart building control providers, and air purification integrators worldwide. Our complete product portfolio includes multi-parameter integrated sensors, compact air quality sensor module designs, and in-depth OEM/ODM volume customization, helping customers build highly efficient smart IAQ sensor systems.
Our production processes are strictly certified to ISO 9001 and IATF 16949 quality management standards. Our CNAS-accredited national laboratory also provides comprehensive particulate concentration simulation and environmental testing, with 3 m³, 5 m³, and 15 m³ test chambers that reproduce the full range of potential sensor application environments.
PRODUCT CATALOG

Dedicated particulate sensing node for ventilation cleanliness, filter-performance evaluation and indoor air quality monitoring. It supports RS485 and UART interfaces, with expandable Modbus protocol support.
Read more
Dedicated NDIR CO2 sensing solution for demand-controlled ventilation, fresh-air units and HVAC air quality management. It supports RS485 and UART interfaces, with expandable Modbus protocol support.
Read more
Dedicated temperature and relative humidity sensing for HVAC environmental monitoring, ventilation control and indoor comfort management. It supports RS485 and UART interfaces, with expandable Modbus protocol support.
Read more
Built on our IAQ multi sensor platform, the A54-22 integrates PM2.5, temperature and humidity sensing for particulate monitoring, ventilation systems and indoor comfort management. It supports RS485 and UART interfaces, with expandable Modbus protocol support.
Read more
Built on our IAQ multi sensor platform, the A54-23 integrates PM2.5, CO2, temperature and humidity sensing for fresh-air units, AHU equipment and commercial HVAC control. It supports RS485 and UART interfaces, with expandable Modbus protocol support.
Read more
Our complete IAQ multi sensor platform integrates PM2.5, CO2, TVOC, temperature and humidity for fresh-air units, AHU systems and smart ventilation control. It supports RS485 and UART interfaces, with expandable Modbus protocol support.
Read more
This configurable IAQ multi sensor platform integrates PM2.5, CO2, temperature, humidity and optional AQS/TVOC sensing with customizable interfaces and relay control.
Read more
Large touchscreen thermostats for integrated HVAC control and indoor air quality monitoring.
View Series
Touchscreen thermostats with a choice of sensing and connectivity configurations for room-level HVAC control.
View Series
A compact 4-inch touchscreen controller with a rechargeable battery for indoor environmental monitoring and smart HVAC control.
View Series
3.5-inch segment and VA display controllers for fresh-air equipment and ventilation control.
View Series
3.5-inch TFT display controllers with multiple configurations for ventilation and indoor air quality management.
View SeriesTECHNICAL DATA
| Parameter | Averaging Time | Guideline Value | Unit |
|---|---|---|---|
| Carbon dioxide | 8 hours | 1800 1000 |
mg/m³ ppm |
| Carbon monoxide | 8 hours | 10 9 |
mg/m³ ppm |
| Formaldehyde | 8 hours | 120 0.1 |
µg/m³ ppm |
| Ozone | 8 hours | 100 0.5 |
µg/m³ ppm |
| Suspended / respirable particulate matter | — | 150 | µg/m³ |
| Volatile organic compounds (VOC) | — | 3 | ppm |
| Air temperature | — | 22.5–25.5 | °C |
| Relative humidity (RH) | — | ≤70 | % |
Indicative guideline values supplied for general IAQ education. Applicable national standards, building type and project requirements take precedence.
IAQ KNOWLEDGE
Indoor air quality describes the conditions inside and around occupied buildings that affect health, comfort and productivity. It is influenced by particulate matter, carbon dioxide, volatile organic compounds, temperature, humidity, outdoor-air delivery, filtration and pollutant sources.
There is no single worldwide IAQ number. WHO air quality guidelines provide health-based reference values for pollutants such as PM2.5, while ASHRAE standards address ventilation and thermal comfort. CO2 is especially useful for demand-controlled ventilation, but ASHRAE cautions that one CO2 threshold alone does not define acceptable IAQ. TVOC readings are best interpreted as trends because compounds, sources and applicable limits vary.
MAXMAC’s configurable IAQ multi sensor platform monitors most of the core operational indicators used in building air-quality management, including PM2.5, CO2, TVOC, temperature and humidity. Through a unified data interface, these measurements can be delivered to fresh-air systems and HVAC controllers, enabling ventilation, filtration and comfort equipment to respond to real-time indoor conditions and help maintain healthier indoor air quality.
CUSTOMIZABLE IAQ MULTI SENSOR PLATFORM
Built on MAXMAC’s configurable IAQ multi sensor platform, your product can combine the air-quality measurements required by its application in one compact assembly. PM1.0, PM2.5 and PM10 detection can be integrated with CO2, AQS/TVOC, temperature and humidity to create a dedicated or multi-parameter IAQ sensor configuration.
One unified data interface consolidates multiple measurements to simplify wiring, PCB layout, firmware development and final product integration. OEM customers can also define the sensing combination, communication method, connector, relay option, firmware logic, calibration strategy, data format, PCB dimensions and mechanical structure.
Choose the particle-size outputs, measurement range, airflow design and calibration required by your application.
Add high-accuracy temperature and humidity data for environmental monitoring and sensor compensation.
Transmit all measurements through UART, I²C, PWM, analog voltage, RS485, CAN, LIN or a custom protocol.
Integrate calibrated NDIR CO₂ measurement into the same compact sensor module and unified data output.
Add AQS or TVOC sensing for odor, pollution-gas and indoor air quality control applications.
Relay control can be added or omitted to match the customer’s control strategy and PCB design.
Combine PM1.0, PM2.5, PM10, CO₂, AQS/TVOC, temperature and humidity functions according to product positioning and installation space.
One connector can transmit multiple sensor outputs, reducing wiring, controller inputs and integration complexity.
Customize relay control, communication protocol, connector, PCB dimensions, firmware logic, calibration and output format.
IAQ CALIBRATION SYSTEM
MAXMAC’s IAQ calibration system validates the complete sensing chain across CO2, PM, VOC/AQS, temperature, humidity and integrated multi-sensor modules. Controlled gas concentrations, environmental chambers, reference instruments, automated calibration benches and production-data traceability help align individual sensing elements and verify each IAQ platform under application-ready conditions before OEM delivery.
MANUFACTURING CAPABILITIES
As a professional IAQ sensor manufacturer, MAXMAC operates its own SMT production area with comprehensive PCB assembly and inspection capabilities. Key processes are completed in-house, including electronic component placement, reflow soldering, AOI inspection, firmware programming and functional testing. This integrated capability accelerates prototyping, pilot production and product iteration while supporting OEM/ODM customization of each air quality sensor module, including sensing combinations, interfaces, PCB dimensions, connectors and firmware logic.
MAXMAC combines automated production lines with flexible manual assembly to match different IAQ product structures, order volumes and customization requirements. Automated equipment protects consistency and delivery efficiency in volume production, while skilled workstations support complex assembly, pilot runs and customized air quality sensor module configurations.
Every production stage is connected to our MES system, enabling full traceability across material batches, PCB assembly, sensor calibration, firmware programming and finished-product inspection. This complete manufacturing data trail gives OEM/ODM customers dependable quality assurance and supports reliable volume delivery from an experienced IAQ sensor manufacturer.
TESTING & VALIDATION
MAXMAC’s CNAS-accredited laboratory brings product verification closer to our engineering and manufacturing teams, significantly shortening validation cycles and accelerating the transition from design to volume production. By identifying design weaknesses, potential failure modes, and risk-control points at an early stage, our laboratory capabilities help prevent issues before they reach customers or enter mass production.
Comprehensive mechanical, electrical, environmental, gas, and microbiological testing enables us to verify product performance under demanding operating conditions. This evidence-based validation process strengthens product stability, long-term reliability, and quality consistency while giving OEM/ODM customers greater confidence throughout development and delivery.
OEM/ODM IAQ PRODUCT INTEGRATION
MAXMAC’s A63 and A23 thermostat families incorporate our configurable IAQ multi sensor platform for PM2.5, CO2, TVOC, temperature and humidity monitoring. In addition to controlling connected HVAC equipment, each thermostat operates as a room-level indoor air quality monitor, displaying real-time environmental measurements directly on its screen.
This room-by-room IAQ sensing architecture provides dependable local air data for demand-based control. When connected to a building automation system and MAXMAC adjustable air-distribution dampers, ventilation can be directed precisely to rooms where air quality requires attention instead of operating the entire fresh-air system at maximum output. This targeted strategy improves indoor air management, occupant comfort and HVAC energy efficiency.
TARGET APPLICATIONS
In modern offices and commercial complexes, integrating a high-accuracy smart IAQ sensor is essential for demand-controlled ventilation (DCV) through the building automation system (BAS). An IAQ multi sensor supplies real-time air-quality data so the HVAC system can adjust outdoor-air volume according to actual conditions, helping the building meet applicable indoor air quality standards while significantly reducing ventilation and conditioning energy consumption.
Deploying an indoor air quality monitor with a CO2 sensor in classrooms, libraries and other educational spaces makes ventilation performance and carbon dioxide concentration visible in real time. The resulting data can prompt additional fresh-air delivery before rooms become stuffy, supporting alertness, comfort and a healthier learning environment for students and staff.
A compact air quality sensor module can be integrated into residential air purifiers, fresh-air units, smart HVAC equipment and desktop monitors. With fast response to indoor air-quality changes, the configurable smart IAQ sensor combines TVOC measurement through an integrated VOC sensor with other environmental inputs for responsive purification and ventilation control.
A protected outdoor air quality sensor can work with an indoor air quality sensor to compare ambient and indoor conditions continuously. The control system uses this inside-versus-outside analysis to select recirculation or fresh-air operation and can automatically restrict outdoor-air intake when pollution, dust or adverse weather would otherwise degrade indoor air quality.
An IAQ sensor is an electronic device that detects and quantifies multiple indoor-air parameters in real time, including CO2, TVOC, PM2.5, temperature and humidity. As an experienced IAQ sensor manufacturer, MAXMAC combines sensing technologies such as NDIR infrared measurement, MOX semiconductor detection, electrochemical sensing and laser scattering according to the required parameter mix.
The sensing elements convert changes in the sampled air into calibrated digital measurements. These readings are delivered through interfaces such as UART or Modbus so building automation and HVAC systems can adjust ventilation, filtration and air-conditioning equipment automatically.
The wholesale IAQ sensor price for an OEM project is mainly determined by three factors:
As a direct manufacturer, MAXMAC provides competitive tiered quotations for qualified B2B partners and long-term bulk programs.
An indoor air quality monitor focuses on occupied spaces and commonly tracks CO2, TVOC, PM2.5, temperature and humidity to support ventilation, comfort and purification control. Its enclosure, airflow path, display and communication options are designed around room-level monitoring and integration with indoor HVAC or building systems.
An outdoor air quality sensor must tolerate wider temperature changes, direct sunlight, rain, wind, dust and other demanding ambient conditions. Outdoor installations therefore typically require a weather-resistant enclosure rated to IP65 or higher, together with protected sampling paths and environmental compensation for reliable atmospheric and industrial-gas monitoring.
Yes. MAXMAC’s configurable IAQ multi sensor platform can be developed around the measurements required by the final product instead of forcing every customer to use the same fixed combination. A project can specify only CO2 and VOC sensing, or combine PM1.0, PM2.5, PM10, CO2, AQS/TVOC, temperature and humidity in different configurations.
The final combination is confirmed according to available installation space, power consumption, target accuracy, response time, airflow design and calibration requirements. This allows the module architecture and cost to remain aligned with the actual application.
Depending on the project, the IAQ sensor module can support UART, I²C, PWM, analog-voltage, RS485, CAN and LIN interfaces, as well as a customer-specific communication protocol. Multiple measurements can be consolidated through one connector and one unified data interface to reduce wiring and controller inputs.
OEM customization can also cover connector type, pin assignment, baud rate, register definitions, data format, reporting interval, alarm thresholds and Modbus mapping. The final interface is selected according to the host controller and system architecture.
Yes. Optional relay control can be integrated into the IAQ multi sensor platform so the module can trigger ventilation equipment, an air purifier, a fan, a damper or another connected device when a configured air-quality threshold is reached.
The required relay channel count, contact rating, control logic, fail-safe behavior and PCB space are reviewed during engineering. The relay can also be omitted when the host HVAC or building controller performs all control functions.
OEM customers can customize the PCB dimensions, mechanical structure, mounting points, connector, pinout, sensor combination and optional relay. Firmware options include output format, sampling and reporting intervals, filtering, compensation logic, alarm thresholds, communication registers and control behavior.
Calibration can be configured around the selected measurements, required accuracy, operating range and application environment. MAXMAC can support prototype validation, pilot production and volume manufacturing with production-data traceability for the approved configuration.
Our product experts will provide the most suitable air solutions and product recommendations.