REFRIGERANT DETECTION APPLICATION

Refrigerant Leak Detection for Heat Pumps & Refrigeration

Dedicated R290 sensing and R744 monitoring for your equipment.

MAXMAC R2 and R3 NDIR sensors bring refrigerant concentration monitoring to heat pumps and refrigeration equipment. Explore dedicated sensor options and application support for your refrigerant, equipment layout and control system.

Discuss Your Application →
Refrigerant Leak Detection engineering illustration with refrigerant equipment and gas sensing components

APPLICATION BENEFITS

Why Choose MAXMAC for Refrigerant Detection?

Combine dedicated gas sensing with product validation and flexible integration support for your equipment development.

01

Dedicated Gas Sensing

Choose R2 for R290 propane detection or R3 for R744 CO₂ monitoring, with the measurement range matched to the refrigerant and application.

02

Reliable Performance

Factory calibration and in-house testing capabilities support evaluation of measurement performance under the conditions specified for each sensor.

03

Flexible Integration

Connect concentration measurements to your equipment controller through the supported interface. Review power, communication and mechanical requirements with MAXMAC.

04

Equipment Safety Requirements

Review applicable IEC and UL safety requirements for your equipment and target market, including 60335-2-40 for heat pumps and air conditioners and 60335-2-89 for commercial refrigeration.

Equipment host controller integration diagramIllustrative refrigerant sensing integration. The selected gas sensing modules connect to a project-defined host controller. Equipment responses and validation are specified for the complete installation.SELECT FOR THE REFRIGERANTExplore R2 R290 refrigerant sensorsR290 / propaneR2 sensor moduleExplore R3 R744 refrigerant sensorsR744 / carbon dioxideR3 sensor moduleEquipment host controllerEvaluate measurements + defined thresholdsDefined equipment responseAlarm / ventilation / shutdown where provided
Illustrative integration concept. Modules, sensing locations and system responses are selected and validated for each project.

R290 & R744 REFRIGERANT SENSING

R290 & R744 Sensing for Heat Pumps & Refrigeration

Choose dedicated sensing for the refrigerant used in your equipment: R2 detects R290 propane, while R3 monitors R744 carbon dioxide. Both provide concentration inputs for the equipment controller, supporting the monitoring and response strategy defined for your heat pump or refrigeration system.

  • R290 propane detection with R2NDIR sensing across a 0–100% LFL measurement range for flammable-refrigerant monitoring.
  • R744 CO₂ monitoring with R3NDIR CO₂ sensing from 400–10,000 ppm as standard, with customization up to 50,000 ppm.
  • Connection to the equipment controllerMatch the selected sensor interface to the controller’s concentration monitoring and defined response strategy.
  • Application-specific evaluationReview the target refrigerant, measurement range, installation environment, target market and applicable safety standards when evaluating the sensor for your equipment.
Explore the R290 HVAC/R Solution

MEASURE, COMMUNICATE & VALIDATE

From Refrigerant Measurement to System Response

The sensing module supplies measurements; the host controller evaluates them and the installed equipment implements the defined response.

  1. 01

    REFRIGERANT MODULE

    Measure

    Measure the target refrigerant with the selected R2 or R3 configuration.

  2. 02

    CONTROL INTERFACE

    Communicate

    Transmit measurements through the selected supported module interface.

  3. 03

    COMPATIBLE CONTROLLER

    Evaluate

    Compare valid gas readings with the equipment’s configured thresholds and response rules.

  4. 04

    CONNECTED HVAC

    Respond

    The equipment executes its defined alarm, ventilation or shutdown response where provided.

  5. 05

    SENSOR + CONTROLLER

    Validate

    Verify the defined system response, ongoing measurements and recovery conditions.

Ongoing measurement

REFRIGERANT DETECTION INSIGHTS

R290 Trends, Safety and Equipment Design

Why is R290 gaining attention in HVAC/R, and what does that mean for leak detection? Explore refrigerant trends, safety considerations and the sensing requirements shaping new equipment designs.

Read the R290 Trends Article

Planning the equipment layout? Read our R290 HVAC design guide for a closer look at refrigerant routing, leak paths and sensor placement.

Heat pump equipment featured in the R290 refrigerant trends article

Discuss Your Refrigerant Detection Application

Tell us your refrigerant, equipment type and integration requirements. Our team will help you review the sensor options for your project.